On Sun, Dec 06, 2015 at 08:52:16PM +0100, Markus Pargmann wrote: > This is the touchscreen conversion queue binding documentation. It uses > the shared imx25 ADC. > > Signed-off-by: Markus Pargmann <mpa@xxxxxxxxxxxxxx> > --- > > Notes: > Changes in v9: > - Updated binding descriptions > > Changes in v5: > - Fix signed/unsigned comparison > - Fix unused variable settling_time by putting it in the correct argument list > - Use continous conversion queue with the repeat feature and a proper > repeat-wait. Previously the touchscreen caused massive number of interrupts. > > .../bindings/input/touchscreen/fsl-mx25-tcq.txt | 35 ++++++++++++++++++++++ > 1 file changed, 35 insertions(+) > create mode 100644 Documentation/devicetree/bindings/input/touchscreen/fsl-mx25-tcq.txt > > diff --git a/Documentation/devicetree/bindings/input/touchscreen/fsl-mx25-tcq.txt b/Documentation/devicetree/bindings/input/touchscreen/fsl-mx25-tcq.txt > new file mode 100644 > index 000000000000..d45e50872114 > --- /dev/null > +++ b/Documentation/devicetree/bindings/input/touchscreen/fsl-mx25-tcq.txt > @@ -0,0 +1,35 @@ > +Freescale mx25 TS conversion queue module > + > +mx25 touchscreen conversion queue module which controls the ADC unit of the > +mx25 for attached touchscreens. > + > +Required properties: > + - compatible: Should be "fsl,imx25-tcq". > + - reg: Memory range of the device. > + - interrupts: Should be the interrupt number associated with this module within > + the tscadc unit (<0>). > + - interrupt-parent: Should be a phandle to the tscadc unit. > + - fsl,wires: Should be '<4>' or '<5>' > + > +Optional properties: > + - fsl,pen-debounce: Pen debounce time in nanoseconds. This and ... > + - fsl,pen-threshold: Pen-down threshold for the touchscreen. This is a value > + between 1 and 4096. It is the ratio between the internal reference voltage > + and the measured voltage after the plate was precharged. Resistence between > + plates and therefore the voltage decreases with pressure so that a smaller > + value is equivalent to a higher pressure. > + - fsl,settling-time: Settling time in nanoseconds. The settling time is before > + the actual touch detection to wait for an even charge distribution in the > + plate. ... this still need units (-ns) appended to the property name. > + > +This device includes two conversion queues which can be added as subnodes. > +The first queue is for the touchscreen, the second for general purpose ADC. > + > +Example: > + tsc: tcq@50030400 { > + compatible = "fsl,imx25-tcq"; > + reg = <0x50030400 0x60>; > + interrupt-parent = <&tscadc>; > + interrupts = <0>; > + fsl,wires = <4>; > + }; > -- > 2.6.2 > > -- > To unsubscribe from this list: send the line "unsubscribe devicetree" in > the body of a message to majordomo@xxxxxxxxxxxxxxx > More majordomo info at http://vger.kernel.org/majordomo-info.html -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html