Re: [ceph-users] [ Ceph MDS MON Config Variables ] Failover Delay issue

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, May 3, 2021 at 6:36 AM Lokendra Rathour
<lokendrarathour@xxxxxxxxx> wrote:
>
> Hi Team,
> I was setting up the ceph cluster with
>
>    - Node Details:3 Mon,2 MDS, 2 Mgr, 2 RGW
>    - Deployment Type: Active Standby
>    - Testing Mode: Failover of MDS Node
>    - Setup : Octopus (15.2.7)
>    - OS: centos 8.3
>    - hardware: HP
>    - Ram:  128 GB on each Node
>    - OSD: 2 ( 1 tb each)
>    - Operation: Normal I/O with mkdir on every 1 second.
>
> T*est Case: Power-off any active MDS Node for failover to happen*
>
> *Observation:*
> We have observed that whenever an active MDS Node is down it takes around*
> 40 seconds* to activate the standby MDS Node.
> on further checking the logs for the new-handover MDS Node we have seen
> delay on the basis of following inputs:
>
>    1. 10 second delay after which Mon calls for new Monitor election
>       1.  [log]  0 log_channel(cluster) log [INF] : mon.cephnode1 calling
>       monitor election

In the process of killing the active MDS, are you also killing a monitor?

-- 
Patrick Donnelly, Ph.D.
He / Him / His
Principal Software Engineer
Red Hat Sunnyvale, CA
GPG: 19F28A586F808C2402351B93C3301A3E258DD79D
_______________________________________________
Dev mailing list -- dev@xxxxxxx
To unsubscribe send an email to dev-leave@xxxxxxx



[Index of Archives]     [CEPH Users]     [Ceph Devel]     [Ceph Large]     [Information on CEPH]     [Linux BTRFS]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]

  Powered by Linux