In Nautilus 14.2.13, we have converted to the minimized ceph.conf file and are now storing our config in the monitors. Previously, radosgw was getting its keyring from /etc/ceph/ceph.client.radosgw.keyring, but now that the ceph.conf has been minimized, the
keyring value was not converted into the monitor k/v store under the radosgw client configuration options and radosgw is looking for the keyring in /var/lib/ceph/radosgw/ceph-radosgw.gw01/keyring instead.
Attempting to put the keyring location into the monitor configuration with "ceph config set ..." fails because it says the keyring value cannot be stored in the monitor config settings. Is there a way to store an alternate keyring location without putting
it in ceph.conf? It's easy enough to work around the issue by using a link or just copying the keyring to the new location, but I was wondering if there is a way to specify the keyring location in the monitor K/V storage.
thanks,
Wyllys Ingersoll
|
_______________________________________________ Dev mailing list -- dev@xxxxxxx To unsubscribe send an email to dev-leave@xxxxxxx