Hello, On Wednesday 19 of February 2014 19:30:52 Michael Mendoza wrote: > Good afternoon. > > We are trying to configure 2 dell R610 with idrac6 EXPRESS in cluster with > redhat 5.10 x64. > > For testing we are using the command fence_ipmilan. We can ping idrac on > the remote host. > > fence_ipmilan -a X.X.X.X -l usern -p xxxx -t 200 -o status -v <-- works > > > fence_ipmilan -a X.X.X.X -l usern -p xxxx -t 200 -o reboot -v > > The problem is the server reboot, but while it reboot the idrac6 reboot > too. so the host A after 120 seconds aprox lost connection and get the > follow message. This seems wrong, when doing a system reboot through IPMI, your BMC should not reboot. does this happen if you use ipmitool or similar tool to reboot the machine? > > > Spawning: '/usr/bin/ipmitool -I lan -H 'X.X.X.X' -U 'usern' -P '[set]' -v > > -v -v chassis power on'... > > Spawned: '/usr/bin/ipmitool -I lan -H 'X.X.X.X' -U 'usern' -P '[set]' -v > > -v -v chassis power on' - PID 10104 > > Looking for: > > 'Password:', val = 1 > > 'Unable to establish LAN', val = 11 > > 'IPMI mutex', val = 14 > > 'Unsupported cipher suite ID', val = 2048 > > 'read_rakp2_message: no support for', val = 2048 > > 'Up/On', val = 0 > > ExpectToken returned 11 > > Reaping pid 10104 > > Failed > > cman version is CMAN-2.0.115.118.e15_10.3 > > > however I have other host with centos 6.4 and CMAN3.0... and the connection > is not lost. I run the same command, the server reboot as well as idrac, > the ping is back and the ipmi connection is not lost.. > > am I doing something wrong? I used the -t and -T option even 300 / 400 and > it doesnt matter, the connection is shut after 120secounds. in centos work > fine. ( I already opened a case with redhat and am waiting answer.) > Thanks -- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster