Hi On my 2 node clusters I have a UPS connected to them. This UPS is programmed to shutdown both nodes of the clusters. Node 2 shutsdown several minutes before node 1. The fence mechanisms I have setup are primarily an APC network power switch and for backup Dell DRAC with fence_ipmilan. If you shutdown a node where the cluster services are chkconfig'd on, and it withdraws cleanly from the cluster on shutdown it sits at system halted and doesn't power off. If no cluster services have ever been started (all chkconfig'd off) and the system is shutdown, it halts and powers off. Now I know the recommendation is for acpi to be turned off but it makes no difference either way, and I have verified both fence mechanisms power hard down the system acpid or not. By not powering down, the UPS continues to have power drawn from it until it's power off timer expires (that the last node send it in halt.local). This has the effect of needlessly reducing battery capacity and lowering protection from multiple consecutive power outages. What causes the system not to power down, I realise this maybe by design, but is it configurable? Thanks Colin ________________________________ This email and any files transmitted with it are confidential and are intended solely for the use of the individual or entity to whom they are addressed. If you are not the original recipient or the person responsible for delivering the email to the intended recipient, be advised that you have received this email in error, and that any use, dissemination, forwarding, printing, or copying of this email is strictly prohibited. If you received this email in error, please immediately notify the sender and delete the original. -- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster