Re: Plugged out blade from bladecenter chassis - fence_bladecenter failed

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
Hi all,

I am using RHCS on IBM bladecenter with blade center fencing. I plugged out a blade from blade center chassis slot and was hoping that failover to occur. However when I did so, I get following message -

fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to obtain correct plug status or plug is not available
fenced[10240]: fence "blade1" failed

Is this supported that if I plug out blade from its slot, then failover occur without manual intervention? If so, which fencing must I use?

You can use option missing_as_off (or --missing-as-off at command line) which returns off even in a case when blade does not exists.

m,
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster


[Index of Archives]     [Corosync Cluster Engine]     [GFS]     [Linux Virtualization]     [Centos Virtualization]     [Centos]     [Linux RAID]     [Fedora Users]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite Camping]

  Powered by Linux