Hi,
On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
Hi all,
I am using RHCS on IBM bladecenter with blade center fencing. I
plugged out a blade from blade center chassis slot and was hoping that
failover to occur. However when I did so, I get following message -
fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to
obtain correct plug status or plug is not available
fenced[10240]: fence "blade1" failed
Is this supported that if I plug out blade from its slot, then
failover occur without manual intervention? If so, which fencing must
I use?
You can use option missing_as_off (or --missing-as-off at command line)
which returns off even in a case when blade does not exists.
m,
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster