Hi.
I got 2 power supplies. But if someone by mistake pull the power cables , is that mean
That the services will not failover ??
Regards
Shalom.
On Wed, Mar 3, 2010 at 1:15 AM, Georgi Stanojevski <glisha@xxxxxxxxx> wrote:
As I understand this is by design.On Tue, Mar 2, 2010 at 6:17 PM, שלום קלמר <sklemer@xxxxxxxxx> wrote:
The only test which failed was - pulling out power cable from one node.The other system try in loop fencing the failed node & services not relocated.
When you pull out the power cables you shutdown the fencing device on that node and the remaining node can't successfully fence it.
The nodes should have redundant power supplies, to avoid single point of failure.
--
Glisha
http://
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster
-- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster