Re: [clvm] Volume group for uuid not found

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, Feb 01, 2010 at 03:34:18PM +0000, Christine Caulfield wrote:
> Is it really two different devices ? If so then clvmd will not work.
> It needs the same view of storage on all systems. Not necessarily
> the same names, but definitely the same actual storage.

So, should I use DRBD with clvm for data mirroring on both nodes?

-- 
   )\._.,--....,'``.
  /,   _.. \   _\  (`._ ,.
 `._.-(,_..'--(,_..'`-.;.' 

--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster

[Index of Archives]     [Corosync Cluster Engine]     [GFS]     [Linux Virtualization]     [Centos Virtualization]     [Centos]     [Linux RAID]     [Fedora Users]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite Camping]

  Powered by Linux