Hi Lon I've applied the patch (see resulting code below) but the patch does not solve the problem. Is there another patch linked to this problem ? Thanks Regards Alain Moullé >> when testing a two-nodes cluster with quorum disk, when >> I poweroff the node1 , node 2 fences well the node 1 and >> failovers the service, but in log of node 2 I have before and after >> the fence success messages many messages like this: >> Apr 24 11:30:04 s_sys@xn3 qdiskd[13740]: <crit> Node 2 is undead. >> Apr 24 11:30:04 s_sys@xn3 qdiskd[13740]: <alert> Writing eviction notice for node 2 >> Apr 24 11:30:05 s_sys@xn3 qdiskd[13740]: <crit> Node 2 is undead. >> Apr 24 11:30:05 s_sys@xn3 qdiskd[13740]: <alert> Writing eviction notice for node 2 >> Apr 24 11:30:06 s_sys@xn3 qdiskd[13740]: <crit> Node 2 is undead. >> Apr 24 11:30:06 s_sys@xn3 qdiskd[13740]: <alert> Writing eviction notice for node 2 >> Apr 24 11:30:07 s_sys@xn3 qdiskd[13740]: <crit> Node 2 is undead. >> Apr 24 11:30:07 s_sys@xn3 qdiskd[13740]: <alert> Writing eviction notice for node 2 >> Apr 24 11:30:08 s_sys@xn3 qdiskd[13740]: <crit> Node 2 is undead. http://sources.redhat.com/git/?p=cluster.git;a=commit;h=b2686ffe984c517110b949d604c54a71800b67c9 Resulting code after patch application in cman/qdisk/main.c : =========================================================== Transition from Online -> Evicted */ if (ni[x].ni_misses > ctx->qc_tko && state_run(ni[x].ni_status.ps_state)) { /* Mark our internal views as dead if nodes miss too many heartbeats... This will cause a master transition if no live master exists. */ if (ni[x].ni_status.ps_state >= S_RUN && ni[x].ni_seen) { clulog(LOG_DEBUG, "Node %d DOWN\n", ni[x].ni_status.ps_nodeid); ni[x].ni_seen = 0; } ni[x].ni_state = S_EVICT; ni[x].ni_status.ps_state = S_EVICT; ni[x].ni_evil_incarnation = ni[x].ni_status.ps_incarnation; /* Write eviction notice if we're the master. */ if (ctx->qc_status == S_MASTER) { clulog(LOG_NOTICE, "Writing eviction notice for node %d\n", ni[x].ni_status.ps_nodeid); qd_write_status(ctx, ni[x].ni_status.ps_nodeid, S_EVICT, NULL, NULL, NULL); if (ctx->qc_flags & RF_ALLOW_KILL) { clulog(LOG_DEBUG, "Telling CMAN to " "kill the node\n"); cman_kill_node(ctx->qc_ch, ni[x].ni_status.ps_nodeid); } } /* Clear our master mask for the node after eviction */ if (mask) clear_bit(mask, (ni[x].ni_status.ps_nodeid-1), sizeof(memb_mask_t)); continue; } -- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster