Re: Event in one failover domain affecting another separate failover domain

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, 2008-04-21 at 13:22 -0400, Kielek, Samuel wrote:

> The issue I have observed is that when server_c (DOMAIN_TWO) had an
> issue that led to it being fenced, the service running on server_a
> (service_one) immediately stopped and relocated to server_b (the
> recovery action is set to "relocate" for both services).

Your cluster.conf would be helpful.

Also, you can increase the log level to 'debug' which would tell you
more; see "Logging Configuration":

  http://sources.redhat.com/cluster/wiki/RGManager

...for more information.

-- Lon



--