Marco Minato wrote:
James Parsons ha scritto:
Marco Minato wrote:
Hi all guys,
I've some problem to change the default action of a fence action.
I want the cluster to shutdown the not-responding node instead of
reboot it.
I've tried to change the default action of the script "fence_apc"
but it seems not to be used from the cluster (as I've renemed it and
still working).
I'm interested to change the action on the plugin.. How is it possible?
Thanks.
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster
In the conf file, in the <device> section, under the clusternode,
where you are specifying the port (outlet) # on your apc switch,
include an attribute stating option="Off", and the node should stay
off when fenced. If it does not, then you need to look towards the
bios settings on the system.
If you want, XXX out your passwords for your devices and send along
your conf file. I will help you add the attribute.
-Jim
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster
yes.. but all the times that I modify d configuration through
system-config-cluster the system change the "option" statement.. I was
searching another way to do it.. Now I've changed from bios the conf
and it's working. it's good for me.
Marco - are you saying that when you added the option="Off" to the conf
file by hand and then started system-config-cluster, that the
option="Off" attribute was removed? That would be a bug :)
Which version of cluster suite and s-c-cluster are you running??
Thanks,
-J
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster