Good day, I'm running Red Hat Cluster Suite on RHEL 4 U3 with APC 7950 ( http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP7950 ) as the fencing device. The version of my fence package is 1.32.18-0. I try to execute some fence_apc commands but I've got errors. Below are the details: [root@orarac01 ~]# fence_apc -a 10.0.6.150 -l apc -p apc -n 02 \ > -o Reboot -T -v failed: unrecognised Reboot response Same error occured for On/Off option. Also, I found a weird problem if I put "2" instead of "02" for the Outlet Number option (-n option). Below are the error message: [root@orarac01 ~]# fence_apc -a 10.0.6.150 -l apc -p apc -n 2 \ > -o Reboot -T -v failed: unrecognised menu response H Anyone have ever faced similar problem with me? Here I attached the apclog for reference. Thanks in advanced for your response. -- Regards, +--------------------------------+ | Mohd Irwan Jamaluddin | | ## System Engineer, | | (o_ Magnifix Sdn. Bhd. | | //\ Tel: +60 3 42705073 | | V_/_ Fax: +60 3 42701960 | | http://www.magnifix.com/ | +--------------------------------+ | "Every successful side needs | | unsung heroes" - fcbayern.de | +--------------------------------+
User Name : apc Password : *** American Power Conversion Network Management Card AOS v2.2.7 (c) Copyright 2002 All Rights Reserved Rack PDU APP v2.2.0 ------------------------------------------------------------------------------- Name : APC for TMNet Date : 06/30/2002 Contact : Mohd Irwan Jamaluddin Time : 10:31:03 Location : Bilik Server Magnifix User : Administrator Up Time : 0 Days 15 Hours 22 Minutes Stat : P+ N+ A+ Switched Rack PDU: Communication Established ------- Control Console ------------------------------------------------------- 1- Device Manager 2- Network 3- System 4- Logout <ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log > ------- Control Console ------------------------------------------------------- 1- Device Manager 2- Network 3- System 4- Logout <ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log > American Power Conversion Network Management Card AOS v2.2.7 (c) Copyright 2002 All Rights Reserved Rack PDU APP v2.2.0 ------------------------------------------------------------------------------- Name : APC for TMNet Date : 06/30/2002 Contact : Mohd Irwan Jamaluddin Time : 10:31:03 Location : Bilik Server Magnifix User : Administrator Up Time : 0 Days 15 Hours 22 Minutes Stat : P+ N+ A+ Switched Rack PDU: Communication Established ------- Control Console ------------------------------------------------------- 1- Device Manager 2- Network 3- System 4- Logout <ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log > ------- Control Console ------------------------------------------------------- 1- Device Manager 2- Network 3- System 4- Logout <ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log > 1 ------- Device Manager -------------------------------------------------------- 1- Phase Monitor/Configuration 2- Outlet Restriction Configuration 3- Outlet Control/Configuration 4- Power Supply Status <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log > 3 ------- Outlet Control/Configuration ------------------------------------------ 1- Outlet 01: Outlet 1 ON 2- Outlet 02: 2 ON 3- Outlet 03: Outlet 3 ON 4- Outlet 04: Outlet 4 ON 5- Outlet 05: Outlet 5 ON 6- Outlet 06: Outlet 6 ON 7- Outlet 07: Outlet 7 ON 8- Outlet 08: Outlet 8 ON 9- Outlet 09: Outlet 9 ON 10- Outlet 10: Outlet 10 ON 11- Outlet 11: Outlet 11 ON 12- Outlet 12: Outlet 12 ON 13- Outlet 13: Outlet 13 ON 14- Outlet 14: Outlet 14 ON 15- Outlet 15: Outlet 15 ON 16- Outlet 16: Outlet 16 ON 17- Master Control/Configuration <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log > 2 ------- Outlet 02: 2 ---------------------------------------------------------- Name : 2 Outlet : 2 State : ON 1- Control Outlet 2 2- Configure Outlet 2 ?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log > 1 ------- Control Outlet -------------------------------------------------------- Name : 2 Outlet : 2 State : ON 1- Immediate On 2- Immediate Off 3- Immediate Reboot 4- Delayed On 5- Delayed Off 6- Delayed Reboot 7- Cancel ?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log > 3 ----------------------------------------------------------------------- Immediate Reboot This command will immediately shutdown outlet 2 named '2', delay for 5 seconds, and then restart. Enter 'YES' to continue or <ENTER> to cancel : Press <ENTER> to continue... ------- Control Outlet -------------------------------------------------------- Name : 2 Outlet : 2 State : ON 1- Immediate On 2- Immediate Off 3- Immediate Reboot 4- Delayed On 5- Delayed Off 6- Delayed Reboot 7- Cancel ?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log > ------- Outlet 02: 2 ---------------------------------------------------------- Name : 2 Outlet : 2 State : ON 1- Control Outlet 2 2- Configure Outlet 2 ?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log > ------- Outlet Control/Configuration ------------------------------------------ 1- Outlet 01: Outlet 1 ON 2- Outlet 02: 2 ON 3- Outlet 03: Outlet 3 ON 4- Outlet 04: Outlet 4 ON 5- Outlet 05: Outlet 5 ON 6- Outlet 06: Outlet 6 ON 7- Outlet 07: Outlet 7 ON 8- Outlet 08: Outlet 8 ON 9- Outlet 09: Outlet 9 ON 10- Outlet 10: Outlet 10 ON 11- Outlet 11: Outlet 11 ON 12- Outlet 12: Outlet 12 ON 13- Outlet 13: Outlet 13 ON 14- Outlet 14: Outlet 14 ON 15- Outlet 15: Outlet 15 ON 16- Outlet 16: Outlet 16 ON 17- Master Control/Configuration <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log > ------- Device Manager -------------------------------------------------------- 1- Phase Monitor/Configuration 2- Outlet Restriction Configuration 3- Outlet Control/Configuration 4- Power Supply Status <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log > ------- Control Console ------------------------------------------------------- 1- Device Manager 2- Network 3- System 4- Logout <ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log >
-- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster