RE: GFS problem

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



> Thank you for the response Francisco (or Francisco Javier? ^_^),

My full name is Francisco Javier :).

> no actually each switch is configured with a single zone including all
of the WWNs of HBAs and storage array ports, i'm going to zone it right
now if you > think that this is advisable. 
>
>But won't the node "sending the reset" affect the array ports (which
obviously MUST be in the same zone)?

Not really, the array ports are prepared for that. It is just that some
HBA do not like receiving those frames.

Javier

--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster

[Index of Archives]     [Corosync Cluster Engine]     [GFS]     [Linux Virtualization]     [Centos Virtualization]     [Centos]     [Linux RAID]     [Fedora Users]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite Camping]