On Thu, 2006-09-14 at 13:20 +0200, Bosse Klykken wrote: > Hi. > > I'm having some issues with a two-node failover cluster on RHEL4/U3 with > kernel 2.6.9-34.0.1.ELsmp, ccs-1.0.3-0, cman-1.0.4-0, fence-1.32.18-0 > and rgmanager-1.9.46-0. After a mishap where I accidentaly caused a > failover of services with power fencing of server01, the system will not > rejoin the cluster after boot. Upgrade to rgmanager 1.9.53 + current magma + magma-plugins. There's an interaction issue between CMAN and rgmanager on 1.9.46 where it's possible that rgmanager could wedge up, causing other services (DLM, fenced) to misbehave. -- Lon -- Linux-cluster mailing list Linux-cluster@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/linux-cluster