Re: qdiskd not properly failing nodes??

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, 2006-09-13 at 10:07 -0400, Lon Hohberger wrote:
> On Tue, 2006-09-12 at 16:12 +0000, danwest@xxxxxxxxxxx wrote:
> 
> > Any idea why the server is not getting rebooted/fenced?
> 
> Did you start fenced ?  Qdisk doesn't handle fencing; it still relies on
> CMAN to handle the fencing bit.

If you want, I could add something to cause the node to reboot itself on
the down-transition when it detects its score is insufficient to
continue as part of the master partition.

E.g., right here:

Sep 12 11:34:02 SERVER1 qdiskd[7495]: <notice> Score insufficient for
master operation (1/2; max=4); downgrading
[ reboot(RB_AUTOBOOT); /* if new configuration thing is set */ ]

-- Lon

--