hai wu wrote:
The one I am using is ERA, which is almost the same as DRAC III/XT,
except it is an embeded DRAC card on motherboard, compared to DRAC
III/XT, which is a seperate added DRAC card. But the telnet prompt
does not have the matching pattern in /sbin/fence_drac file, so I just
added the following to the file, which works now.
Thanks,
Hai
Hai,
So, you are saying that if you are using a DRAC ERA card, and you set
the $drac_version in the script to $DRAC_VERSION_III_XT, then the fence
agent works? If so, we'll patch the agent accordingly. Please confirm.
-J
if (/Dell Embedded Remote Access Controller \(ERA\)\nFirmware
Version/m)
{
$drac_version = $DRAC_VERSION_III_XT;
} else {
if (/.*\((DRAC[^)]*)\)/m)
{
print "detected drac version '$1'\n" if $verbose;
$drac_version = $1 unless defined $drac_version;
print "WARNING: detected drac version '$1' but using "
. "user defined version '$drac_version'\n"
if ($drac_version ne $1);
}
else
{
print "WARNING: unable to detect DRAC version '$_'\n";
$drac_version = $DRAC_VERSION_UNKNOWN;
}
}
On 8/9/06, *James Parsons* <jparsons@xxxxxxxxxx
<mailto:jparsons@xxxxxxxxxx>> wrote:
hai wu wrote:
> I got the following prompts after telneting to the drac port,
maybe a
> simple upgrade for the firmware would fix this issue:
>
> Dell Embedded Remote Access Controller (ERA)
> Firmware Version 3.31 (Build 07.15)
> Login:
>
> Thanks,
> Hai
Oops. Sorry. Unsupported version. If you want, you could hack the
agent
script (it is in perl) and get it to accept that version and just
*see*
if it works -- it might. I tried looking for documentation for that
firmware rev and couldn't google any. If you know of some, drop me a
line and maybe we can get something working - or at least know if it
*will ever* work. :)
-J
BTW, the agent supports DRAC III/XT, DRAC MC, and DRAC 4/I.
>
> On 8/9/06, *James Parsons* < jparsons@xxxxxxxxxx
<mailto:jparsons@xxxxxxxxxx>
> <mailto:jparsons@xxxxxxxxxx <mailto:jparsons@xxxxxxxxxx>>> wrote:
>
> hai wu wrote:
>
> > I got the following errors after "reboot -fn" on
erd-tt-eproof1,
> which
> > script do I need to change?
> >
> > Aug 9 15:35:40 erd-tt-eproof2 kernel: CMAN: removing node
> > erd-tt-eproof1 from t
> > he cluster : Missed too many heartbeats
> > Aug 9 15:35:40 erd-tt-eproof2 fenced[3437]:
erd-tt-eproof1 not a
> > cluster member
> > after 0 sec post_fail_delay
> > Aug 9 15:35:40 erd-tt-eproof2 fenced[3437]: fencing node
> "erd-tt-eproof1"
> > Aug 9 15:35:42 erd-tt-eproof2 fenced[3437]: agent
"fence_drac"
> > reports: WARNING
> > : unable to detect DRAC version ' Dell Embedded Remote Access
> > Controller (ERA) F
> > irmware Version 3.31 (Build 07.15) ' WARNING: unsupported DRAC
> version
> > '__unknow
> > n__' failed: unable to determine power state
> >
> > This is DRAC on Dell PE2650.
> > Thanks,
> > Hai
>
> Do you know what DRAC version you are using? Can you please
telnet
> into
> the drac port and find out what it says when it starts your
session?
>
> Thanks,
>
> -J
>
> --
> Linux-cluster mailing list
> Linux-cluster@xxxxxxxxxx <mailto:Linux-cluster@xxxxxxxxxx>
<mailto: Linux-cluster@xxxxxxxxxx <mailto:Linux-cluster@xxxxxxxxxx>>
> https://www.redhat.com/mailman/listinfo/linux-cluster
> < https://www.redhat.com/mailman/listinfo/linux-cluster>
>
>
>------------------------------------------------------------------------
>
>--
>Linux-cluster mailing list
> Linux-cluster@xxxxxxxxxx <mailto:Linux-cluster@xxxxxxxxxx>
>https://www.redhat.com/mailman/listinfo/linux-cluster
>
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx <mailto:Linux-cluster@xxxxxxxxxx>
https://www.redhat.com/mailman/listinfo/linux-cluster
------------------------------------------------------------------------
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster
--
Linux-cluster mailing list
Linux-cluster@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/linux-cluster