Re: Rhcs4 fence with no hardware power switch

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, 2005-08-29 at 02:26 +0000, nattapon viroonsri wrote:
> I use RedHat cluster v4 for HA and have no power switch hardware
> When i disconnected  network cable for client access resource , Failover 
> have occur as expect
> But the server that was disconnect network cable not be rebooted or fenced 
> like rhcs V3(even no power switch).  And the failed server  can't not join 
> cluster again.

Eep, no failover should have occurred if you don't have fencing.

> In Rhcs V3. it reboot fail node automatically without hardware power switch
> 
> So, Have anyway to reboot failed node(network problem or server problem) 
> without use hardware power switch to make failnode to clean state again ?

You need fencing hardware with RHCS4/RHEL4.  I'd check ebay if you're
not looking to spend a lot, you can get a WTI NPS115 for pretty cheap
nowadays (under $100!).

You can run with manual fencing, but no automatic recovery will occur,
and this isn't a supported solution.

-- Lon

--

Linux-cluster@xxxxxxxxxx
http://www.redhat.com/mailman/listinfo/linux-cluster

[Index of Archives]     [Corosync Cluster Engine]     [GFS]     [Linux Virtualization]     [Centos Virtualization]     [Centos]     [Linux RAID]     [Fedora Users]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite Camping]