I forgot one man page. The attached patch converts them. Bastian -- "What terrible way to die." "There are no good ways." -- Sulu and Kirk, "That Which Survives", stardate unknown
=== fenced.8 ================================================================== --- fenced.8 (revision 317) +++ fenced.8 (revision 318) @@ -5,20 +5,17 @@ .\" modify, copy, or redistribute it subject to the terms and conditions .\" of the GNU General Public License v.2. -.tl 'fenced(8)''fenced(8)' +.TH fenced 8 -\fBNAME\fP -.in +7 -fenced- the I/O Fencing daemon +.SH NAME +fenced - the I/O Fencing daemon -.in -\fBSYNOPSIS\fP -.in +7 -\fBfenced [options]\fP -.sp -.in -\fBDESCRIPTION\fP -.in +7 +.SH SYNOPSIS +.B +fenced +[\fIOPTION\fR]... + +.SH DESCRIPTION The fencing daemon, \fBfenced\fP, should be run on every node that will use CLVM or GFS. It should be started after the node has joined the CMAN cluster (fenced is only used with CMAN; it is not used with GULM/SLM/RLM.) @@ -38,7 +35,7 @@ it depends on CCS to provide cluster.conf information. The fencing daemon calls fencing agents according to cluster.conf information. -Node failure +.SS Node failure When a domain member fails, the actual fencing must be completed before GFS recovery can begin. This means any delay in carrying out the fencing @@ -54,7 +51,7 @@ node is not fenced and all recovery must wait until the failed node rejoins the cluster. -Domain startup +.SS Domain startup When the domain is first created in the cluster (by the first node to join it) and subsequently enabled (by the cluster gaining quorum) any nodes @@ -89,13 +86,7 @@ are fenced by power cycling. If nodes are fenced by disabling their SAN access, then unnecessarily fencing a node is usually less disruptive. - -.sp -.in -\fBCONFIGURATION FILE\fP -.in +7 -.sp - +.SH CONFIGURATION FILE Fencing daemon behavior can be controlled by setting options in the cluster.conf file under the section <fence_daemon> </fence_daemon>. See above for complete descriptions of these values. The delay values are in @@ -121,59 +112,30 @@ <fence_daemon clean_start="0"> </fence_daemon> - -.sp -.in -\fBOPTIONS\fP -.in +7 -.sp - +.SH OPTIONS Command line options override corresonding values in cluster.conf. - +.TP \fB-j\fP \fIsecs\fP -.in +7 Post-join fencing delay -.in -.sp - +.TP \fB-f\fP \fIsecs\fP -.in +7 Post-fail fencing delay -.in -.sp - +.TP \fB-c\fP -.in +7 All nodes are in a clean state to start. -.in -.sp - +.TP \fB-D\fP -.in +7 Enable debugging code and don't fork into the background. -.in -.sp - +.TP \fB-n\fP \fIname\fP -.in +7 Name of the fence domain, "default" if none. -.in -.sp - +.TP \fB-V\fP -.in +7 Print the version information and exit. -.in -.sp - +.TP \fB-h\fP -.in +7 Print out a help message describing available options, then exit. -.in -.sp -.in -7 -\fBSEE ALSO\fP -.in +7 +.SH SEE ALSO gfs(8), fence(8)
Attachment:
signature.asc
Description: Digital signature