On 10/11/24 10:07, Frank Schilder wrote:
Only problem is that setting an OSD OUT might not be sticky. If the OSD reboots for some reason it might mark itself IN again.
The Ceph cluster distinguishes between manually marked out ("ceph osd out N") and automatically marked out, when an OSD is down for more than 10 minutes.
Manually marked out OSDs do not mark themselves in again. Regards -- Robert Sander Heinlein Consulting GmbH Schwedter Str. 8/9b, 10119 Berlin https://www.heinlein-support.de Tel: 030 / 405051-43 Fax: 030 / 405051-19 Amtsgericht Berlin-Charlottenburg - HRB 220009 B Geschäftsführer: Peer Heinlein - Sitz: Berlin _______________________________________________ ceph-users mailing list -- ceph-users@xxxxxxx To unsubscribe send an email to ceph-users-leave@xxxxxxx