Re: OSD service specs in mixed environment

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 





On 27-06-2024 10:56, Frédéric Nass wrote:
Hi Torkil, Ruben,

Hi Frédéric

I see two theoretical ways to do this without additional OSD service. One that probably doesn't work :-) and another one that could work depending on how the orchestrator prioritize its actions based on services criteria.

The one that probably doesn't work is by specifying multiple exact size with an OR filter in osd.fast service (with no modifications to the osd.slow service):

---
service_type: osd
service_id: fast
service_name: osd.fast
placement:
   host_pattern: '*'
spec:
   data_devices:
     size: 400G
     size: 7680G
   filter_logic: OR
   objectstore: bluestore

I doubt the orchestrator can handle multiple exact size criteria.

I am pretty sure this wouldn't work because it would also match HDDs.

> The one that may work is:

---
service_type: osd
service_id: fast
service_name: osd.fast
placement:
    host_pattern: '*'
spec:
    data_devices:
      rotational: 0              <-- remove size criteria
    filter_logic: AND
    objectstore: bluestore
---
service_type: osd
service_id: slow
service_name: osd.slow
placement:
    host_pattern: '*'
spec:
    block_db_size: 290966113186
    data_devices:
      rotational: 1
    db_devices:
      rotational: 0
      size: '1000G:6900G'
      model: NVME-QQQQ-987       <-- specify NVMe's model
    filter_logic: AND
    objectstore: bluestore
---

This may work if the orchestrator gives priority to services with more specific criteria. If not then you may want to add SSDs vendor's criteria (if 3.2TB and 6.4TB SSDs drives are from the same vendor AND NVMEs are from another) to the osd.fast service.

We considered trying to test if some ordering or priority could sort this but we resigned to just do multiple specs which wouldn't depend on undocumented behavior that might change.

service_type: osd
service_id: fast
service_name: osd.fast
placement:
  host_pattern: '*'
spec:
  data_devices:
    rotational: 0
    size: :1000G
  filter_logic: AND
  objectstore: bluestore
---
service_type: osd
service_id: fast2
service_name: osd.fast2
placement:
  host_pattern: '*'
spec:
  data_devices:
    rotational: 0
    size: '6990G:'
  filter_logic: AND
  objectstore: bluestore

It might be better to go with even more specs and use models instead of sizes for everything not HDD but we have a lot of different models so as long as it's not broken this will do.

Thanks for the suggestions!

Mvh.

Torkil

Regards,
Frédéric.

----- Le 26 Juin 24, à 8:48, Torkil Svensgaard torkil@xxxxxxxx a écrit :

Hi

We have a bunch of HDD OSD hosts with DB/WAL on PCI NVMe, either 2 x
3.2TB or 1 x 6.4TB. We used to have 4 SSDs pr node for journals before
bluestore and those have been repurposed for an SSD pool (wear level is
fine).

We've been using the following service specs to avoid the PCI NVMe
devices for bluestore being provisioned as OSDs:

---
service_type: osd
service_id: fast
service_name: osd.fast
placement:
   host_pattern: '*'
spec:
   data_devices:
     rotational: 0
     size: :1000G  <-- only use devices smaller than 1TB = not PCI NVMe
   filter_logic: AND
   objectstore: bluestore
---
service_type: osd
service_id: slow
service_name: osd.slow
placement:
   host_pattern: '*'
spec:
   block_db_size: 290966113186
   data_devices:
     rotational: 1
   db_devices:
     rotational: 0
     size: '1000G:' <-- only use devices larger than 1TB for DB/WAL
   filter_logic: AND
   objectstore: bluestore
---

We just bought a few 7.68 TB SATA SSDs to add to the SSD pool which
aren't being picked up by the osd.fast spec because they are too large
and they could also be picked up as DB/WAL with the current specs.

As far as I can determine there is no way to achieve what I want with
the existing specs, as I can't filter on PCI vs SATA, only rotational or
not, I can't use size, as it only can define an in between range, not an
outside range, and I can't use filter_logic OR for the sizes because I
need the rotational qualifier to be AND.

I can do a osd.fast2 spec with size: 7000G: and change the db_devices
size for osd.slow to something like 1000G:7000G but curious to see if
anyone would have a different suggestion?

Mvh.

Torkil

--
Torkil Svensgaard
Sysadmin
MR-Forskningssektionen, afs. 714
DRCMR, Danish Research Centre for Magnetic Resonance
Hvidovre Hospital
Kettegård Allé 30
DK-2650 Hvidovre
Denmark
Tel: +45 386 22828
E-mail: torkil@xxxxxxxx
_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx