On Fri, Feb 02 2024 at 07:51:36 -0700, Josh Baergen wrote:
On Fri, Feb 2, 2024 at 7:44 AM Ruben Vestergaard <rubenv@xxxxxxxx> wrote:
Is the RBD client performing partial object reads? Is that even a thing?
Yup! The rados API has both length and offset parameters for reads
(https://docs.ceph.com/en/latest/rados/api/librados/#c.rados_aio_read)
and writes (https://docs.ceph.com/en/latest/rados/api/librados/#c.rados_aio_write).
Ah! That was easy. And good to know.
Thanks!
-R