Re: Disk device path changed - cephadm faild to apply osd service

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



However since it's already broken now - is this the correct way to fix it?


###

ceph orch ls --service_name=<service-name> --export > myservice.yaml

-> change my device path to the correct one

ceph orch apply -i myservice.yaml [--dry-run]
###


Thanks
________________________________
Von: Eugen Block <eblock@xxxxxx>
Gesendet: Mittwoch, 2. August 2023 08:13:41
An: ceph-users@xxxxxxx
Betreff:  Re: Disk device path changed - cephadm faild to apply osd service

Do you really need device paths in your configuration? You could use
other criteria like disk sizes, vendors, rotational flag etc. If you
really want device paths you'll probably need to ensure they're
persistent across reboots via udev rules.

Zitat von Kilian Ries <mail@xxxxxxxxxxxxxx>:

> Hi,
>
>
> it seems that after reboot / OS update my disk labels / device paths
> may have changed. Since then i get an error like this:
>
>
>
> CEPHADM_APPLY_SPEC_FAIL: Failed to apply 1 service(s): osd.osd-12-22_hdd-2
>
>
>
> ###
>
>
> RuntimeError: cephadm exited with an error code: 1, stderr:Non-zero
> exit code 1 from /bin/docker run --rm --ipc=host
> --stop-signal=SIGTERM --net=host --entrypoint /usr/sbin/ceph-volume
> --privileged --group-add=disk --init -e
> CONTAINER_IMAGE=quay.io/ceph/ceph@sha256:9e2fd45a080aea67d1935d7d9a9025b6db2e8be9173186e068a79a0da5a54ada -e NODE_NAME=ceph-osd07.intern -e CEPH_USE_RANDOM_NONCE=1 -e CEPH_VOLUME_OSDSPEC_AFFINITY=osd-12-22_hdd-2 -e CEPH_VOLUME_SKIP_RESTORECON=yes -e CEPH_VOLUME_DEBUG=1 -v /var/run/ceph/01578d80-6c97-46ba-9327-cb2b13980916:/var/run/ceph:z -v /var/log/ceph/01578d80-6c97-46ba-9327-cb2b13980916:/var/log/ceph:z -v /var/lib/ceph/01578d80-6c97-46ba-9327-cb2b13980916/crash:/var/lib/ceph/crash:z -v /dev:/dev -v /run/udev:/run/udev -v /sys:/sys -v /run/lvm:/run/lvm -v /run/lock/lvm:/run/lock/lvm -v /:/rootfs -v /tmp/ceph-tmp2cvmr5lf:/etc/ceph/ceph.conf:z -v /tmp/ceph-tmpb38cuw7q:/var/lib/ceph/bootstrap-osd/ceph.keyring:z
> quay.io/ceph/ceph@sha256:9e2fd45a080aea67d1935d7d9a9
>  025b6db2e8be9173186e068a79a0da5a54ada lvm batch --no-auto /dev/sdm
> /dev/sdn /dev/sdo /dev/sdp /dev/sdq --db-devices /dev/sdg --yes
> --no-systemd
>
> /bin/docker: stderr Traceback (most recent call last):
>
> /bin/docker: stderr   File "/usr/sbin/ceph-volume", line 11, in <module>
>
> /bin/docker: stderr     load_entry_point('ceph-volume==1.0.0',
> 'console_scripts', 'ceph-volume')()
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/main.py", line 41, in
> __init__
>
> /bin/docker: stderr     self.main(self.argv)
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/decorators.py", line
> 59, in newfunc
>
> /bin/docker: stderr     return f(*a, **kw)
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/main.py", line 153, in
> main
>
> /bin/docker: stderr     terminal.dispatch(self.mapper, subcommand_args)
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/terminal.py", line
> 194, in dispatch
>
> /bin/docker: stderr     instance.main()
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/devices/lvm/main.py",
> line 46, in main
>
> /bin/docker: stderr     terminal.dispatch(self.mapper, self.argv)
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/terminal.py", line
> 192, in dispatch
>
> /bin/docker: stderr     instance = mapper.get(arg)(argv[count:])
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/devices/lvm/batch.py",
> line 348, in __init__
>
> /bin/docker: stderr     self.args = parser.parse_args(argv)
>
> /bin/docker: stderr   File "/usr/lib64/python3.6/argparse.py", line
> 1734, in parse_args
>
> /bin/docker: stderr     args, argv = self.parse_known_args(args, namespace)
>
> /bin/docker: stderr   File "/usr/lib64/python3.6/argparse.py", line
> 1766, in parse_known_args
>
> /bin/docker: stderr     namespace, args =
> self._parse_known_args(args, namespace)
>
> /bin/docker: stderr   File "/usr/lib64/python3.6/argparse.py", line
> 1954, in _parse_known_args
>
> /bin/docker: stderr     positionals_end_index =
> consume_positionals(start_index)
>
> /bin/docker: stderr   File "/usr/lib64/python3.6/argparse.py", line
> 1931, in consume_positionals
>
> /bin/docker: stderr     take_action(action, args)
>
> /bin/docker: stderr   File "/usr/lib64/python3.6/argparse.py", line
> 1824, in take_action
>
> /bin/docker: stderr     argument_values = self._get_values(action,
> argument_strings)
>
> /bin/docker: stderr   File "/usr/lib64/python3.6/argparse.py", line
> 2279, in _get_values
>
> /bin/docker: stderr     value = [self._get_value(action, v) for v in
> arg_strings]
>
> /bin/docker: stderr   File "/usr/lib64/python3.6/argparse.py", line
> 2279, in <listcomp>
>
> /bin/docker: stderr     value = [self._get_value(action, v) for v in
> arg_strings]
>
> /bin/docker: stderr   File "/usr/lib64/python3.6/argparse.py", line
> 2294, in _get_value
>
> /bin/docker: stderr     result = type_func(arg_string)
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/util/arg_validators.py", line
> 116, in __call__
>
> /bin/docker: stderr     return self._format_device(self._is_valid_device())
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/util/arg_validators.py", line
> 127, in _is_valid_device
>
> /bin/docker: stderr     super()._is_valid_device(raise_sys_exit=False)
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/util/arg_validators.py", line
> 104, in _is_valid_device
>
> /bin/docker: stderr     super()._is_valid_device()
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/util/arg_validators.py", line
> 69, in _is_valid_device
>
> /bin/docker: stderr     super()._is_valid_device()
>
> /bin/docker: stderr   File
> "/usr/lib/python3.6/site-packages/ceph_volume/util/arg_validators.py", line
> 47, in _is_valid_device
>
> /bin/docker: stderr     raise RuntimeError("Device {} has
> partitions.".format(self.dev_path))
>
> /bin/docker: stderr RuntimeError: Device /dev/sdq has partitions.
>
> Traceback (most recent call last):
>
>   File
> "/var/lib/ceph/01578d80-6c97-46ba-9327-cb2b13980916/cephadm.0317efb4d3a353d5a77e82f4a4f52582f06970d6aba66473daecf92e26ee3a51", line 9309, in
> <module>
>
>     main()
>
>   File
> "/var/lib/ceph/01578d80-6c97-46ba-9327-cb2b13980916/cephadm.0317efb4d3a353d5a77e82f4a4f52582f06970d6aba66473daecf92e26ee3a51", line 9297, in
> main
>
>     r = ctx.func(ctx)
>
>   File
> "/var/lib/ceph/01578d80-6c97-46ba-9327-cb2b13980916/cephadm.0317efb4d3a353d5a77e82f4a4f52582f06970d6aba66473daecf92e26ee3a51", line 1941, in
> _infer_config
>
>     return func(ctx)
>
>   File
> "/var/lib/ceph/01578d80-6c97-46ba-9327-cb2b13980916/cephadm.0317efb4d3a353d5a77e82f4a4f52582f06970d6aba66473daecf92e26ee3a51", line 1872, in
> _infer_fsid
>
>     return func(ctx)
>
>   File
> "/var/lib/ceph/01578d80-6c97-46ba-9327-cb2b13980916/cephadm.0317efb4d3a353d5a77e82f4a4f52582f06970d6aba66473daecf92e26ee3a51", line 1969, in
> _infer_image
>
>     return func(ctx)
>
>   File
> "/var/lib/ceph/01578d80-6c97-46ba-9327-cb2b13980916/cephadm.0317efb4d3a353d5a77e82f4a4f52582f06970d6aba66473daecf92e26ee3a51", line 1859, in
> _validate_fsid
>
>     return func(ctx)
>
>   File
> "/var/lib/ceph/01578d80-6c97-46ba-9327-cb2b13980916/cephadm.0317efb4d3a353d5a77e82f4a4f52582f06970d6aba66473daecf92e26ee3a51", line 5366, in
> command_ceph_volume
>
>     out, err, code = call_throws(ctx, c.run_cmd())
>
>   File
> "/var/lib/ceph/01578d80-6c97-46ba-9327-cb2b13980916/cephadm.0317efb4d3a353d5a77e82f4a4f52582f06970d6aba66473daecf92e26ee3a51", line 1661, in
> call_throws
>
>     raise RuntimeError('Failed command: %s' % ' '.join(command))
>
>
> ###
>
>
>
> /dev/sdg is my boot device at the moment wich was formerly /dev/sda.
>
>
> Is it safe to edit the ceph orch yaml file and change the device
> pathes to the new format? Like this:
>
>
> ceph orch ls --service_name=<service-name> --export > myservice.yaml
>
>
> vi (change device pathes in spec -> data_devices -> path |
> db_devices -> path)
>
>
> ceph orch apply -i myservice.yaml [--dry-run]
>
>
>
> Is that ok / expected behaviour? Or is there a better way?
>
>
> However can see that mgr detects new devices in ceph orch log:
>
>
> mgr.ceph-mon03.lrfomu [INF] Detected new or changed devices on ceph-osd07
>
>
>
> Regards,
>
> Kilian
>
>
> _______________________________________________
> ceph-users mailing list -- ceph-users@xxxxxxx
> To unsubscribe send an email to ceph-users-leave@xxxxxxx


_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx
_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx



[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Ceph Dev]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]


  Powered by Linux