Hi, we had an issue with an old cluster, where we put disks from one host to another. We destroyed the disks and added them as new OSDs, but since then the mgr daemon were restarting in 120s intervals. I tried to debug it a bit, and it looks like the balancer is the problem. I tried to disable it and create a plan on my own, but then the active manager just stops and the failover takes place. Any idea how to easily fix it or debug it further? I am currently trying to resolve the backfillfull issue by hand (ceph osd reweight) and then to restart all OSD hosts. -- Die Selbsthilfegruppe "UTF-8-Probleme" trifft sich diesmal abweichend im groüen Saal. _______________________________________________ ceph-users mailing list -- ceph-users@xxxxxxx To unsubscribe send an email to ceph-users-leave@xxxxxxx