Hi Ceph Users, I am currently evaluating different cluster layouts and as a test I stopped two of my three monitors while client traffic was running on the nodes.? Only when I restartet an OSD all PGs which were related to that OSD went down, but the rest were still active and serving requests. A second try ran for 5:30 Hours without a hitch after which I aborted the Test since nothing was happening. Now I want to know; Is this behavior by design? It strikes me as odd that this more or less undefined state is still operational. Thanks Johannes Liebl _______________________________________________ ceph-users mailing list -- ceph-users@xxxxxxx To unsubscribe send an email to ceph-users-leave@xxxxxxx