recently I thought about erasure coding and how to set k+m in a useful way also taking into account the number of hosts available for ceph. Say I would have this setup:

The cluster has 6 hosts and I want to allow two *hosts* to fail without loosing data. So I might choose k+m as 4+2 with redundancy at host level, but isn't this a little unwise?

What would happen if:

1. two disks would fail where both failed disks are not on the same host? I think ceph would be able to find a PG distributed across all hosts avoiding the two failed disks, so ceph would be able to repair and reach a healthy status after a while?

2. Two complete hosts would fail say because of broken power supplies. In this case ceph would no longer be able to repair the damage because there are no two more "free" remaining hosts to satisfy the 4+2 rule (with redundancy on host level). So data would not be lost but the cluster might stop delivering data and would be unable to repair and thus would also be unable to become healthy again?

Right or wrong?

Thanks a lot
Rainer
--
Rainer Krienke, Uni Koblenz, Rechenzentrum, A22, Universitaetsstrasse  1
56070 Koblenz, Web: http://www.uni-koblenz.de/~krienke, Tel: +49261287 1312
PGP: http://www.uni-koblenz.de/~krienke/mypgp.html, Fax: +49261287 1001312
_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx



[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Ceph Dev]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]


  Powered by Linux