Thanks for the quick reply, Frank. Sorry, the graphs/attachment where filtered. Here is an example of one latency: https://drive.google.com/file/d/1qSWmSmZ6JXVweepcoY13ofhfWXrBi2uZ/view?usp=sharing <https://drive.google.com/file/d/1qSWmSmZ6JXVweepcoY13ofhfWXrBi2uZ/view?usp=sharing> I’m aware that the overall performance depends on the slowest OSD. What I expect is that bluefs_buffered_io=true set on one OSD reflects in dropped latencies for that particular OSD. Best regards, Björn > Am 13.02.2021 um 07:39 schrieb Frank Schilder <frans@xxxxxx>: > > The graphs were forgotten or filtered out. > > Changing the buffered_io value on one host will not change client IO performance as its always the slowest OSD thats decisive. However, it should have an effect on the IOP/s load reported by iostat on the disks on the host. > > Does setting bluefs_buffered_io=true on all hosts have an effect on client IO? Note that it might need a restart even if the documentation says otherwise. > > Best regards, > ================= > Frank Schilder > AIT Risø Campus > Bygning 109, rum S14 > > ________________________________________ > From: Björn Dolkemeier <b.dolkemeier@xxxxxxx> > Sent: 13 February 2021 07:16:06 > To: ceph-users@xxxxxxx > Subject: Latency increase after upgrade 14.2.8 to 14.2.16 > > Hi, > > after upgrading Ceph from 14.2.8 to 14.2.16 we experienced increased latencies. There were no changes in hardware, configuration, workload or networking, just a rolling-update via ceph-ansible on running production cluster. The cluster consists of 16 OSDs (all SSD) over 4 Nodes. The VMs served via RBD from this cluster currently suffer on i/o wait cpu. > > These are some latencies that are increased after the update: > - op_r_latency > - op_w_latency > - kv_final_lat > - state_kv_commiting_lat > - submit_lat > - subop_w_latency > > Do these latencies point to KV/RocksDB? > > These are some latencies which are NOT increased after the update: > - kv_sync_lat > - kv_flush_lat > - kv_commit_lat > > I attached one graph showing the massive increase after the update. > > I tried setting bluefs_buffered_io=true (as it’s default value was changed and it was mentioned as performance relevant) for all OSDs in one host but this does not make a difference. > > The ceph.conf is fairly simple: > > [global] > cluster network = xxx > fsid = xxx > mon host = xxx > public network = xxx > > [osd] > osd memory target = 10141014425 > > Any ideas what to try? Help appreciated. > > Björn > > > > > > > -- > > dbap GmbH > phone +49 251 609979-0 / fax +49 251 609979-99 > Heinr.-von-Kleist-Str. 47, 48161 Muenster, Germany > http://www.dbap.de > > dbap GmbH, Sitz: Muenster > HRB 5891, Amtsgericht Muenster > Geschaeftsfuehrer: Bjoern Dolkemeier > > _______________________________________________ > ceph-users mailing list -- ceph-users@xxxxxxx > To unsubscribe send an email to ceph-users-leave@xxxxxxx _______________________________________________ ceph-users mailing list -- ceph-users@xxxxxxx To unsubscribe send an email to ceph-users-leave@xxxxxxx