Re: Can 16 server grade ssd's be slower then 60 hdds? (no extra journals)

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Sorry I am not fully aware of what has been already discussed in this 
thread. But can't you flash these LSI logic cards to jbod? I have done 
this with my 9207 with sas2flash.

I have attached my fio test of the Micron 5100 Pro/5200 SSDs 
MTFDDAK1T9TCC. They perform similar to my samsung sm863a 1,92TB. Only 
thing weird, is that the rw-4k is 3x slower on the micron.





-----Original Message-----
To: 'Reed Dier'
Cc: 'ceph-users@xxxxxxx'
Subject:  Re: Can 16 server grade ssd's be slower then 60 
hdds? (no extra journals)

Thank you. I was working in this direction. The situation is a lot 
better. But I think I can get still far better.

I could set the controller to writethrough, direct and no read ahead for 
the ssds.
But I cannot disable the pdcache ☹ there is an option set in the 
controller "Block SSD Write Disk Cache Change = Yes" which does not 
permit to deactivate the ssd cache. I could not find any solution in 
google for this controller (LSI MegaRAID SAS 9271-8i) to change this 
setting.

I don’t know how much performance gain it will be to deactivate the ssd 
cache. At least the micron 5200max has capacitor so I hope it is safe 
for data loss in case if power failure. I wrote a request to lsi / 
Broadcom if they know how I can change this setting. This is really 
annyoing.

I will check the cpu power settings. I rode also somewhere it can 
improve iops a lot. (if its bad set)

At the moment I get 600iops 4k random write 1 thread and 1 iodepth. I 
get 40K - 4k random iops for some instances with 32iodepth. Its not the 
world but a lot better then before. Read around 100k iops. For 16 ssd's 
and 2 x dual 10G nic.

I was reading that good tunings and hardware config can get more then 
2000 iops on single thread out of the ssds. I know thet ceph does not 
shine with single thread. But 600 iops is not very much...

philipp

-----Ursprüngliche Nachricht-----
Von: Reed Dier <reed.dier@xxxxxxxxxxx>
Gesendet: Dienstag, 01. September 2020 22:37
An: VELARTIS Philipp Dürhammer <p.duerhammer@xxxxxxxxxxx>
Cc: ceph-users@xxxxxxx
Betreff: Re:  Can 16 server grade ssd's be slower then 60 
hdds? (no extra journals)

If using storcli/perccli for manipulating the LSI controller, you can 
disable the on-disk write cache with:
storcli /cx/vx set pdcache=off

You can also ensure that you turn off write caching at the controller 
level with storcli /cx/vx set iopolicy=direct storcli /cx/vx set 
wrcache=wt

You can also tweak the readahead value for the vd if you want, though 
with an ssd, I don't think it will be much of an issue.
storcli /cx/vx set rdcache=nora

I'm sure the megacli alternatives are available with some quick 
searches.

May also want to check your c-states and p-states to make sure there 
isn't any aggressive power saving features getting in the way.

Reed

> On Aug 31, 2020, at 7:44 AM, VELARTIS Philipp Dürhammer 
<p.duerhammer@xxxxxxxxxxx> wrote:
> 
> We have older LSi Raid controller with no HBA/JBOD option. So we 
expose the single disks as raid0 devices. Ceph should not be aware of 
cache status?
> But digging deeper in to it it seems that 1 out of 4 serves is 
performing a lot better and has super low commit/applay rates while the 
other have a lot mor (20+) on heavy writes. This just applys fore the 
ssd. For the hdds I cant see a difference...
> 
> -----Ursprüngliche Nachricht-----
> Von: Frank Schilder <frans@xxxxxx>
> Gesendet: Montag, 31. August 2020 13:19
> An: VELARTIS Philipp Dürhammer <p.duerhammer@xxxxxxxxxxx>; 
> 'ceph-users@xxxxxxx' <ceph-users@xxxxxxx>
> Betreff: Re: Can 16 server grade ssd's be slower then 60 hdds? (no 
> extra journals)
> 
> Yes, they can - if volatile write cache is not disabled. There are 
many threads on this, also recent. Search for "disable write cache" 
and/or "disable volatile write cache".
> 
> You will also find different methods of doing this automatically.
> 
> Best regards,
> =================
> Frank Schilder
> AIT Risø Campus
> Bygning 109, rum S14
> 
> ________________________________________
> From: VELARTIS Philipp Dürhammer <p.duerhammer@xxxxxxxxxxx>
> Sent: 31 August 2020 13:02:45
> To: 'ceph-users@xxxxxxx'
> Subject:  Can 16 server grade ssd's be slower then 60 
> hdds? (no extra journals)
> 
> I have a productive 60 osd's cluster. No extra Journals. Its 
performing okay. Now I added an extra ssd Pool with 16 Micron 5100 MAX. 
And the performance is little slower or equal to the 60 hdd pool. 4K 
random as also sequential reads. All on dedicated 2 times 10G Network. 
HDDS are still on filestore. SSD on bluestore. Ceph Luminous.
> What should be possible 16 ssd's vs. 60 hhd's no extra journals?
> 
> _______________________________________________
> ceph-users mailing list -- ceph-users@xxxxxxx To unsubscribe send an 
> email to ceph-users-leave@xxxxxxx 
> _______________________________________________
> ceph-users mailing list -- ceph-users@xxxxxxx To unsubscribe send an 
> email to ceph-users-leave@xxxxxxx

_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx To unsubscribe send an 
email to ceph-users-leave@xxxxxxx


_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx




[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Ceph Dev]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]


  Powered by Linux