Re: collectd Ceph metric

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



 
The 'xx-xxxx.conf' are mine, custom. So I would not have to merge 
changes with newer /etc/collectd.conf rpm updates. 

I would suggest get a small configuration that is working, set debug 
logging[0], and increase the configuration until it fails with little 
steps. Load plugin ceph empty, configure then one osd, fails? try mgr?, 
try mon? etc


[0] Try something like this?
LoadPlugin logfile

<Plugin logfile>
#    not compiled with debug?
#    also not writing to the logfile
        LogLevel debug
     File "/tmp/collectd.log"
#    File STDOUT
        Timestamp true
#       PrintSeverity false
</Plugin>


-----Original Message-----
Cc: ceph-users@xxxxxxxxxxxxxx
Subject: Re:  collectd Ceph metric

Is there any instruction to install the plugin configuration?

Attach my RHEL/collectd configuration file under /etc/ directory.
On RHEL:
    [rdma@rdmarhel0 collectd.d]$ pwd
    /etc/collectd.d
    [rdma@rdmarhel0 collectd.d]$ tree .
    .

    0 directories, 0 files
    [rdma@rdmarhel0 collectd.d]$
    
I've also checked the collectd configuration file under Ubuntu, there's 
no 11-network.conf or 12-memory.conf .etc. However, it could still 
collect the cpu and memory information.
On Ubuntu:
   nstcc1@nstcloudcc1:collectd$ pwd
   /etc/collectd
   nstcc1@nstcloudcc1:collectd$ tree .
   .
   ├── collectd.conf
   ├── collectd.conf.d
   │   ├── filters.conf
   │   └── thresholds.conf
   └── collection.conf

   1 directory, 4 files
   nstcc1@nstcloudcc1:collectd$

B.R.
Changcheng

On 10:56 Mon 21 Oct, Marc Roos wrote:
> 
> Your collectd starts without the ceph plugin ok? 
> 
> I have also your error " didn't register a configuration callback", 
> because I configured debug logging, but did not enable it by loading 
> the plugin 'logfile'. Maybe it is the order in which your 
> configuration files a read (I think this used to be important with 
> collectd)
> 
> I have only in my collectd.conf these two lines:
> Include "/etc/collectd.d"
> LoadPlugin syslog
> 
> And in /etc/collectd.d/ these files:
> 10-custom.conf    (with network section for influx)
> 11-network.conf   (ethx)
> 12-memory.conf
> 50-ceph.conf
> 51-ipmi.conf
> 52-ipmi-power.conf
> 53-disk.conf
> 
> 
> 
> 
> [0] journalctl -u collectd.service
> Oct 21 10:29:39 c02 collectd[1017750]: Exiting normally.
> Oct 21 10:29:39 c02 systemd[1]: Stopping Collectd statistics daemon...
> Oct 21 10:29:39 c02 collectd[1017750]: collectd: Stopping 5 read 
> threads.
> Oct 21 10:29:39 c02 collectd[1017750]: collectd: Stopping 5 write 
> threads.
> Oct 21 10:29:40 c02 systemd[1]: Stopped Collectd statistics daemon.
> Oct 21 10:29:53 c02 systemd[1]: Starting Collectd statistics daemon...
> Oct 21 10:29:53 c02 collectd[1031939]: plugin_load: plugin "syslog" 
> successfully loaded.
> Oct 21 10:29:53 c02 collectd[1031939]: plugin_load: plugin "network" 
> successfully loaded.
> Oct 21 10:29:53 c02 collectd[1031939]: Found a configuration for the 
> `logfile' plugin, but the plugin isn't loaded or didn't register a 
> configuration callback.
> Oct 21 10:29:53 c02 collectd[1031939]: Found a configuration for the 
> `logfile' plugin, but the plugin isn't loaded or didn't register a 
> configuration callback.
> Oct 21 10:29:53 c02 collectd[1031939]: Found a configuration for the 
> `logfile' plugin, but the plugin isn't loaded or didn't register a 
> configuration callback.
> Oct 21 10:29:53 c02 collectd[1031939]: network plugin: The 
> `MaxPacketSize' must be between 1024 and 65535.
> Oct 21 10:29:53 c02 collectd[1031939]: network plugin: Option 
> `CacheFlush' is not allowed here.
> Oct 21 10:29:53 c02 collectd[1031939]: plugin_load: plugin "interface" 

> successfully loaded.
> Oct 21 10:29:53 c02 collectd[1031939]: plugin_load: plugin "memory" 
> successfully loaded.
> Oct 21 10:29:53 c02 collectd[1031939]: plugin_load: plugin "ceph" 
> successfully loaded.
> Oct 21 10:29:53 c02 collectd[1031939]: plugin_load: plugin "ipmi" 
> successfully loaded.
> Oct 21 10:29:53 c02 collectd[1031939]: ipmi plugin: Legacy 
> configuration found! Please update your config file.
> Oct 21 10:29:53 c02 collectd[1031939]: plugin_load: plugin "exec" 
> successfully loaded.
> Oct 21 10:29:53 c02 collectd[1031939]: plugin_load: plugin "disk" 
> successfully loaded.
> Oct 21 10:29:53 c02 collectd[1031939]: Systemd detected, trying to 
> signal readyness.
> Oct 21 10:29:53 c02 systemd[1]: Started Collectd statistics daemon.
> Oct 21 10:29:53 c02 collectd[1031939]: Initialization complete, 
> entering read-loop.
> Oct 21 10:30:04 c02 collectd[1031939]: ipmi plugin: sensor_list_add: 
> Ignore sensor `PS2 Status power_supply (10.2)` of `main`, because it 
> is discrete (0x8)! Its type:
> Oct 21 10:30:04 c02 collectd[1031939]: ipmi plugin: sensor_list_add: 
> Ignore sensor ` management controller firmware (46.4)` of `main`, 
> because it isn't readable! Its Oct 21 10:30:04 c02 collectd[1031939]: 
> ipmi plugin: sensor_list_add:
> Ignore sensor ` management controller firmware (46.3)` of `main`, 
> because it isn't readable! Its Oct 21 10:30:04 c02 collectd[1031939]: 
> ipmi plugin: sensor_list_add:
> Ignore sensor ` management controller firmware (46.2)` of `main`, 
> because it isn't readable! Its Oct 21 10:30:04 c02 collectd[1031939]: 
> ipmi plugin: sensor_list_add:
> Ignore sensor ` management controller firmware (46.1)` of `main`, 
> because it isn't readable! Its Oct 21 10:30:04 c02 collectd[1031939]: 
> ipmi plugin: sensor_list_add:
> Ignore sensor `PS1 Status power_supply (10.1)` of `main`, because it 
> is discrete (0x8)! Its type:
> Oct 21 10:30:04 c02 collectd[1031939]: ipmi plugin: sensor_list_add: 
> Ignore sensor `Chassis Intru system_chassis (23.1)` of `main`, because 

> it is discrete (0x5)! Its Oct 21 10:30:04 c02 collectd[1031939]: ipmi 
> plugin: sensor_list_add:
> Ignore sensor `HDD Status disk_drive_bay (26.1)` of `main`, because it 

> is discrete (0xd)! Its typ Oct 21 10:30:55 c02 collectd[1031939]: ipmi 

> plugin: sensor_read_handler:
> sensor `FANB fan_cooling (29.8)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `FANA fan_cooling (29.7)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `FAN6 fan_cooling (29.6)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `FAN5 fan_cooling (29.5)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `FAN1 fan_cooling (29.1)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P2-DIMMH3 TEMP memory_device (32.94)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P2-DIMMH2 TEMP memory_device (32.93)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P2-DIMMG3 TEMP memory_device (32.90)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P2-DIMMG2 TEMP memory_device (32.89)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P2-DIMMF3 TEMP memory_device (32.86)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P2-DIMME3 TEMP memory_device (32.82)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P1-DIMMD3 TEMP memory_device (32.78)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P1-DIMMD2 TEMP memory_device (32.77)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P1-DIMMC3 TEMP memory_device (32.74)` of `main` not present.
> Oct 21 10:30:55 c02 collectd[1031939]: ipmi plugin: 
sensor_read_handler: 
> sensor `P1-DIMMC2 TEMP memory_device (32.73)` of `main` not present.
> 
> 
> 
> 
> 
> -----Original Message-----
> Cc: ceph-users@xxxxxxxxxxxxxx
> Subject: Re:  collectd Ceph metric
> 
> On 10:16 Mon 21 Oct, Marc Roos wrote:
> > I have the same. I do not think ConvertSpecialMetricTypes is
> necessary. 
> > 
> > <LoadPlugin ceph>
> >   Globals true
> > </LoadPlugin>
> > 
> > <Plugin ceph>
> >   LongRunAvgLatency false
> >   ConvertSpecialMetricTypes true
> >   <Daemon "osd.1">
> >     SocketPath "/var/run/ceph/ceph-osd.1.asok"
> >   </Daemon>
> > 
> Same configuration, but there's below error after "systemctl restart 
> collectd"
> Have you ever hit this error before?
> 
> =================Log start===========
> Oct 21 16:22:52 rdmarhel0 collectd[768000]: Found a configuration for 
> the `ceph' plugin, but the plugin isn't loaded or didn't register a 
> configuration callback.
> Oct 21 16:22:52 rdmarhel0 systemd[1]: Unit collectd.service entered 
> failed state.
> Oct 21 16:22:52 rdmarhel0 collectd[768000]: Found a configuration for 
> the `ceph' plugin, but the plugin isn't loaded or didn't register a 
> configuration callback.
> Oct 21 16:22:52 rdmarhel0 systemd[1]: collectd.service failed.
> Oct 21 16:22:52 rdmarhel0 collectd[768000]: There is a `Daemon' block 
> within the configuration for the ceph plugin. The plugin either only 
> expects "simple" configuration statements or wasn Oct 21 16:22:52 
> rdmarhel0 systemd[1]: collectd.service holdoff time over, scheduling 
> restart.
> Oct 21 16:22:52 rdmarhel0 systemd[1]: Stopped Collectd statistics 
> daemon.
> -- Subject: Unit collectd.service has finished shutting down 
> =================Log end===========
> 
> B.R.
> Changcheng
> > 
> > 
> > -----Original Message-----
> > Cc: ceph-users@xxxxxxxxxxxxxx
> > Subject: Re:  collectd Ceph metric
> > 
> > On 09:50 Mon 21 Oct, Marc Roos wrote:
> > > 
> > > I am, collectd with luminous, and upgraded to nautilus and 
> > > collectd
> > > 5.8.1-1.el7 this weekend. Maybe increase logging or so. 
> > > I had to wait a long time before collectd was supporting the 
> > > luminous release, maybe it is the same with octopus (=15?)
> > > 
> > @Roos: Do you mean that you could run collectd(5.8.1) with 
> > Ceph-Nautilus? Below is my collectd configuration with Ceph-Octopus:
> > 
> >     <LoadPlugin ceph>
> >     <Plugin ceph>
> >       <Daemon "osd.0">
> >         SocketPath "/var/run/ceph/ceph-osd.0.asok"
> >       </Daemon>
> >     </Plugin>
> > 
> > Is there anything wrong?
> > 
> > > 
> > >  
> > > 
> > > -----Original Message-----
> > > From: Liu, Changcheng [mailto:changcheng.liu@xxxxxxxxx]
> > > Sent: maandag 21 oktober 2019 9:41
> > > To: ceph-users@xxxxxxxxxxxxxx
> > > Subject:  collectd Ceph metric
> > > 
> > > Hi all,
> > >    Does anyone succeed to use collectd/ceph plugin to collect ceph
> > >    cluster data?
> > >    I'm using collectd(5.8.1) and Ceph-15.0.0. collectd failed to 
get
> > >    cluster data with below error:
> > >    "collectd.service holdoff time over, scheduling restart"
> > > 
> > > Regards,
> > > Changcheng
> > > _______________________________________________
> > > ceph-users mailing list
> > > ceph-users@xxxxxxxxxxxxxx
> > > http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
> > > 
> > > 
> > 
> > 
> 
> 


_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com