Thank you, Konstantin.
I'll resize the rocksDB devices then and see what happens if we turn
the warnings back on.
Thanks!
Eugen
Zitat von Konstantin Shalygin <k0ste@xxxxxxxx>:
On 9/26/19 9:45 PM, Eugen Block wrote:
I'm following the discussion for a tracker issue [1] about
spillover warnings that affects our upgraded Nautilus cluster.
Just to clarify, would a resize of the rocksDB volume (and
expanding with 'ceph-bluestore-tool bluefs-bdev-expand...') resolve
that or do we have to recreate every OSD?
Yes, this works since Luminous 12.2.11
k
_______________________________________________
ceph-users mailing list -- ceph-users@xxxxxxx
To unsubscribe send an email to ceph-users-leave@xxxxxxx