Re: HW failure cause client IO drops

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Mandi! M Ranga Swami Reddy
  In chel di` si favelave...

> Hello - Recevenlt we had an issue with storage node's battery failure, which
> cause ceph client IO dropped to '0' bytes. Means ceph cluster couldn't perform
> IO operations on the cluster till the node takes out. This is not expected from
> Ceph, as some HW fails, those respective OSDs should mark as out/down and IO
> should go as is..
> Please let me know if anyone seen the similar behavior and is this issue
> resolved?

'battery' mean 'CMOS battery'?


OSDs and MONs need accurate clock sync between them. So, if a node
reboot with a clock skew more than (AFAI Remember well) 5 seconds, OSD
does not start.

Provide a stable NTP server for all your OSDs and MONs, and restart
OSDs after clock are in sync.

-- 
dott. Marco Gaiarin				        GNUPG Key ID: 240A3D66
  Associazione ``La Nostra Famiglia''          http://www.lanostrafamiglia.it/
  Polo FVG   -   Via della Bontà, 7 - 33078   -   San Vito al Tagliamento (PN)
  marco.gaiarin(at)lanostrafamiglia.it   t +39-0434-842711   f +39-0434-842797

		Dona il 5 PER MILLE a LA NOSTRA FAMIGLIA!
      http://www.lanostrafamiglia.it/index.php/it/sostienici/5x1000
	(cf 00307430132, categoria ONLUS oppure RICERCA SANITARIA)
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com