Re: Problems after migrating to straw2 (to enable the balancer)

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Thanks for the prompt reply

Indeed I have different racks with different weights. 
Below the ceph osd tree" output

[root@ceph-mon-01 ~]# ceph osd tree
ID CLASS WEIGHT    TYPE NAME                 STATUS REWEIGHT PRI-AFF 
-1       272.80426 root default                                      
-7       109.12170     rack Rack11-PianoAlto                         
-8        54.56085         host ceph-osd-04                          
30   hdd   5.45609             osd.30            up  1.00000 1.00000 
31   hdd   5.45609             osd.31            up  1.00000 1.00000 
32   hdd   5.45609             osd.32            up  1.00000 1.00000 
33   hdd   5.45609             osd.33            up  1.00000 1.00000 
34   hdd   5.45609             osd.34            up  1.00000 1.00000 
35   hdd   5.45609             osd.35            up  1.00000 1.00000 
36   hdd   5.45609             osd.36            up  1.00000 1.00000 
37   hdd   5.45609             osd.37            up  1.00000 1.00000 
38   hdd   5.45609             osd.38            up  1.00000 1.00000 
39   hdd   5.45609             osd.39            up  1.00000 1.00000 
-9        54.56085         host ceph-osd-05                          
40   hdd   5.45609             osd.40            up  1.00000 1.00000 
41   hdd   5.45609             osd.41            up  1.00000 1.00000 
42   hdd   5.45609             osd.42            up  1.00000 1.00000 
43   hdd   5.45609             osd.43            up  1.00000 1.00000 
44   hdd   5.45609             osd.44            up  1.00000 1.00000 
45   hdd   5.45609             osd.45            up  1.00000 1.00000 
46   hdd   5.45609             osd.46            up  1.00000 1.00000 
47   hdd   5.45609             osd.47            up  1.00000 1.00000 
48   hdd   5.45609             osd.48            up  1.00000 1.00000 
49   hdd   5.45609             osd.49            up  1.00000 1.00000 
-6       109.12170     rack Rack15-PianoAlto                         
-3        54.56085         host ceph-osd-02                          
10   hdd   5.45609             osd.10            up  1.00000 1.00000 
11   hdd   5.45609             osd.11            up  1.00000 1.00000 
12   hdd   5.45609             osd.12            up  1.00000 1.00000 
13   hdd   5.45609             osd.13            up  1.00000 1.00000 
14   hdd   5.45609             osd.14            up  1.00000 1.00000 
15   hdd   5.45609             osd.15            up  1.00000 1.00000 
16   hdd   5.45609             osd.16            up  1.00000 1.00000 
17   hdd   5.45609             osd.17            up  1.00000 1.00000 
18   hdd   5.45609             osd.18            up  1.00000 1.00000 
19   hdd   5.45609             osd.19            up  1.00000 1.00000 
-4        54.56085         host ceph-osd-03                          
20   hdd   5.45609             osd.20            up  1.00000 1.00000 
21   hdd   5.45609             osd.21            up  1.00000 1.00000 
22   hdd   5.45609             osd.22            up  1.00000 1.00000 
23   hdd   5.45609             osd.23            up  1.00000 1.00000 
24   hdd   5.45609             osd.24            up  1.00000 1.00000 
25   hdd   5.45609             osd.25            up  1.00000 1.00000 
26   hdd   5.45609             osd.26            up  1.00000 1.00000 
27   hdd   5.45609             osd.27            up  1.00000 1.00000 
28   hdd   5.45609             osd.28            up  1.00000 1.00000 
29   hdd   5.45609             osd.29            up  1.00000 1.00000 
-5        54.56085     rack Rack17-PianoAlto                         
-2        54.56085         host ceph-osd-01                          
 0   hdd   5.45609             osd.0             up  1.00000 1.00000 
 1   hdd   5.45609             osd.1             up  1.00000 1.00000 
 2   hdd   5.45609             osd.2             up  1.00000 1.00000 
 3   hdd   5.45609             osd.3             up  1.00000 1.00000 
 4   hdd   5.45609             osd.4             up  1.00000 1.00000 
 5   hdd   5.45609             osd.5             up  1.00000 1.00000 
 6   hdd   5.45609             osd.6             up  1.00000 1.00000 
 7   hdd   5.45609             osd.7             up  1.00000 1.00000 
 8   hdd   5.45609             osd.8             up  1.00000 1.00000 
 9   hdd   5.45609             osd.9             up  1.00000 1.00000 
[root@ceph-mon-01 ~]#

On Mon, Jan 14, 2019 at 3:13 PM Dan van der Ster <dan@xxxxxxxxxxxxxx> wrote:
On Mon, Jan 14, 2019 at 3:06 PM Massimo Sgaravatto
<massimo.sgaravatto@xxxxxxxxx> wrote:
>
> I have a ceph luminous cluster running on CentOS7 nodes.
> This cluster has 50 OSDs, all with the same size and all with the same weight.
>
> Since I noticed that there was a quite "unfair" usage of OSD nodes (some used at 30 %, some used at 70 %) I tried to activate the balancer.
>
> But the balancer doesn't start I guess because of this problem:
>
> [root@ceph-mon-01 ~]# ceph osd crush weight-set create-compat
> Error EPERM: crush map contains one or more bucket(s) that are not straw2
>
>
> So I issued the command to convert from straw to straw2 (all the clients are running luminous):
>
>
> [root@ceph-mon-01 ~]# ceph osd crush set-all-straw-buckets-to-straw2
> Error EINVAL: new crush map requires client version hammer but require_min_compat_client is firefly
> [root@ceph-mon-01 ~]# ceph osd set-require-min-compat-client jewel
> set require_min_compat_client to jewel
> [root@ceph-mon-01 ~]# ceph osd crush set-all-straw-buckets-to-straw2
> [root@ceph-mon-01 ~]#
>
>
> After having issued the command, the cluster went in WARNING state because ~ 12 % objects were misplaced.
>
> Is this normal ?
> I read somewhere that the migration from straw to straw2 should trigger a data migration only if the OSDs have different sizes, which is not my case.

The relevant sizes to compare are the crush buckets across which you
are replicating.
Are you replicating host-wise or rack-wise?
Do you have hosts/racks with a different crush weight (e.g. different
crush size).
Maybe share your `ceph osd tree`.

Cheers, dan



>
>
> The cluster is still recovering, but what is worrying me is that it looks like that data are being moved to the most used OSDs and the MAX_AVAIL value is decreasing quite quickly.
>
> I hope that the recovery can finish without causing problems: then I will immediately activate the balancer.
>
> But, if some OSDs are getting too full, is it safe to decrease their weights  while the cluster is still being recovered ?
>
> Thanks a lot for your help
> Of course I can provide other info, if needed
>
>
> Cheers, Massimo
>
> _______________________________________________
> ceph-users mailing list
> ceph-users@xxxxxxxxxxxxxx
> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]