"one OSD's data to generate three copies on new failure domain" because ceph assumes it is correct. Get the pg's that are going to be moved and scrub them? I think the problem is more why these objects are inconsistent before you even do the migration -----Original Message----- From: poi [mailto:poiiiicen@xxxxxxxxx] Sent: zondag 19 augustus 2018 16:41 To: ceph-users@xxxxxxxxxxxxxx Subject: Silent data corruption may destroy all the object copies after data migration Hello! Recently, we did data migration from one failure domain to another by changing the logical pool's crush_rule (ceph osd pool set <pool_name> crush_rule <rule_name>). But after the migration, we found that some objects were destroyed and their copies on different OSDs were also destroyed. After taking some experiments, we found that for one object, the data migration uses only one OSD's data to generate three copies on new failure domain, and do not check the crc before migration by default. We tried both filestore and bluestore, and the result is the same. Once silent data corruption appears on one OSD, and when doing data migration, the data source of some objects happens to be it, the new object after the migration will be wrong on all copies. Is there any way to ensure the correctness of data when data migration? We tried to set filestore_sloppy_crc up or do deep scrub, but the cost is too high. The experiment we did is something like below: First create some OSDs and devide them into two different root. -> # ceph osd tree ID CLASS WEIGHT TYPE NAME STATUS REWEIGHT PRI-AFF -7 0.05699 root root1 -5 0.05699 host ceph01 3 hdd 0.01900 osd.3 up 1.00000 1.00000 4 hdd 0.01900 osd.4 up 1.00000 1.00000 5 hdd 0.01900 osd.5 up 1.00000 1.00000 -1 0.05846 root default -3 0.05846 host ceph02 0 hdd 0.01949 osd.0 up 1.00000 1.00000 1 hdd 0.01949 osd.1 up 1.00000 1.00000 2 hdd 0.01949 osd.2 up 1.00000 1.00000 Then create a replicated pool on root default. Note we set the failure domain to OSD. ceph osd pool create test 128 128 Next we put an object into the pool. -> # cat txt 123 -> # rados -p test put test_copy txt -> # rados -p test get test_copy - 123 Then we make OSD.0 down, and change its data of object test_copy. -> # ceph-objectstore-tool --data-path /var/lib/ceph/osd/ceph-0 -> test_copy get-bytes 123 -> # ceph-objectstore-tool --data-path /var/lib/ceph/osd/ceph-0 -> test_copy set-bytes 120txt Next we start OSD.0 and do data migration. ceph osd pool set test crush_rule root1_rule Finally we try to get the object by rados and ceph-objectstore-tool -> # rados -p test get test_copy - error getting test/test_copy: (5) Input/output error -> # ceph-objectstore-tool --data-path /var/lib/ceph/osd/ceph-3 -> test_copy get-bytes 120 -> # ceph-objectstore-tool --data-path /var/lib/ceph/osd/ceph-4 -> test_copy get-bytes 120 -> # ceph-objectstore-tool --data-path /var/lib/ceph/osd/ceph-5 -> test_copy get-bytes 120 The data of test_copy on OSD.3 OSD.4 OSD.5 is from OSD.0 which has the silent data corruption. Our config is below: -> # cat /etc/ceph/ceph.conf [global] fsid = 96c5f802-ca66-4d12-974f-5b5658a18353 mon_initial_members = ceph00 mon_host = 10.18.192.27 auth_cluster_required = none auth_service_required = none auth_client_required = none public_network = 10.18.192.0/24 [mon] mon_allow_pool_delete = true The ceph version is below -> # ceph -v ceph version 12.2.7 (3ec878d1e53e1aeb47a9f619c49d9e7c0aa384d5) luminous (stable) Thanks. _______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com