Erasure coded pools - overhead, data distribution

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi everyone, we run a cluster for our customer, ubuntu 16.04, ceph luminous 12.2.4 - its use is exclusively for cephFS now. We use multiple cephFS(i'm aware it's an experimental feature, but it works fine so far) for our storage purposes. The data pools for all the cephFS filesystems are erasure coded(metadata pools are replicated and in the ssd root). The nodes vary in their weight/disk count/disk size, the ceph osd tree currently looks like this (the orphaned osds at the end have been moved recently)

ID  CLASS WEIGHT    TYPE NAME            STATUS REWEIGHT PRI-AFF
-11         0.75995 root ssd
-12         0.18999     host ceph-s1-ssd
 60   hdd   0.09499         osd.60           up  1.00000 1.00000
 61   hdd   0.09499         osd.61           up  1.00000 1.00000
-13         0.18999     host ceph-s2-ssd
 62   hdd   0.09499         osd.62           up  1.00000 1.00000
 63   hdd   0.09499         osd.63           up  1.00000 1.00000
-14         0.18999     host ceph-s3-ssd
 64   hdd   0.09499         osd.64           up  1.00000 1.00000
 65   hdd   0.09499         osd.65           up  1.00000 1.00000
-15         0.18999     host ceph-s4-ssd
 66   hdd   0.09499         osd.66           up  1.00000 1.00000
 67   hdd   0.09499         osd.67           up  1.00000 1.00000
 -1       563.05499 root default
 -3        36.38373     host ceph-s1
  0   hdd   1.81898         osd.0            up  1.00000 1.00000
  1   hdd   1.81898         osd.1            up  1.00000 1.00000
  2   hdd   1.81898         osd.2            up  1.00000 1.00000
  3   hdd   1.81898         osd.3            up  1.00000 1.00000
  4   hdd   1.81898         osd.4            up  1.00000 1.00000
  5   hdd   1.81898         osd.5            up  1.00000 1.00000
 38   hdd   5.45798         osd.38           up  1.00000 1.00000
113   hdd   7.27698         osd.113          up  1.00000 1.00000
117   hdd   7.27698         osd.117          up  1.00000 1.00000
118   hdd   5.45789         osd.118          up  1.00000 1.00000
-29        34.56670     host ceph-s10
 86   hdd   1.81929         osd.86           up  1.00000 1.00000
 87   hdd   1.81929         osd.87           up  1.00000 1.00000
 88   hdd   1.81929         osd.88           up  1.00000 1.00000
 89   hdd   1.81929         osd.89           up  1.00000 1.00000
 90   hdd   1.81929         osd.90           up  1.00000 1.00000
 91   hdd   1.81929         osd.91           up  1.00000 1.00000
115   hdd   5.45789         osd.115          up  1.00000 1.00000
124   hdd   7.27730         osd.124          up  1.00000 1.00000
125   hdd   5.45789         osd.125          up  1.00000 1.00000
154   hdd   5.45789         osd.154          up  1.00000 1.00000
-31        50.93839     host ceph-s11
  6   hdd   7.27699         osd.6            up  1.00000 1.00000
 92   hdd   5.45789         osd.92           up  1.00000 1.00000
 93   hdd   1.81929         osd.93           up  1.00000 1.00000
 94   hdd   1.81929         osd.94           up  1.00000 1.00000
 95   hdd   1.81929         osd.95           up  1.00000 1.00000
100   hdd   7.27730         osd.100          up  1.00000 1.00000
109   hdd   1.81929         osd.109          up  1.00000 1.00000
110   hdd   1.81929         osd.110          up  1.00000 1.00000
143   hdd  10.91399         osd.143          up  1.00000 1.00000
155   hdd   5.45789         osd.155          up  1.00000 1.00000
156   hdd   5.45789         osd.156          up  1.00000 1.00000
-33        37.29559     host ceph-s13
  8   hdd   1.81929         osd.8            up  1.00000 1.00000
  9   hdd   1.81929         osd.9            up  1.00000 1.00000
 23   hdd   5.45799         osd.23           up  1.00000 1.00000
 58   hdd   1.81929         osd.58           up  1.00000 1.00000
 59   hdd   3.63860         osd.59           up  1.00000 1.00000
 80   hdd   1.81929         osd.80           up  1.00000 1.00000
 96   hdd   1.81929         osd.96           up  1.00000 1.00000
111   hdd   2.72890         osd.111          up  1.00000 1.00000
126   hdd   5.45789         osd.126          up  1.00000 1.00000
157   hdd   5.45789         osd.157          up  1.00000 1.00000
158   hdd   5.45789         osd.158          up  1.00000 1.00000
-35        43.66319     host ceph-s14
 97   hdd   1.81929         osd.97           up  1.00000 1.00000
 98   hdd   1.81929         osd.98           up  1.00000 1.00000
 99   hdd   1.81929         osd.99           up  1.00000 1.00000
101   hdd   1.81929         osd.101          up  1.00000 1.00000
107   hdd   1.81929         osd.107          up  1.00000 1.00000
112   hdd   1.81929         osd.112          up  1.00000 1.00000
127   hdd   7.27730         osd.127          up  1.00000 1.00000
128   hdd   3.63860         osd.128          up  1.00000 1.00000
129   hdd   3.63860         osd.129          up  1.00000 1.00000
130   hdd   3.63860         osd.130          up  1.00000 1.00000
133   hdd   3.63860         osd.133          up  1.00000 1.00000
159   hdd   5.45789         osd.159          up  1.00000 1.00000
160   hdd   5.45789         osd.160          up  1.00000 1.00000
-37        43.66319     host ceph-s15
 22   hdd   5.45799         osd.22           up  1.00000 1.00000
102   hdd   1.81929         osd.102          up  1.00000 1.00000
103   hdd   5.45789         osd.103          up  1.00000 1.00000
104   hdd   1.81929         osd.104          up  1.00000 1.00000
105   hdd   1.81929         osd.105          up  1.00000 1.00000
106   hdd   5.45789         osd.106          up  1.00000 1.00000
131   hdd   3.63860         osd.131          up  1.00000 1.00000
132   hdd   3.63860         osd.132          up  1.00000 1.00000
134   hdd   3.63860         osd.134          up  1.00000 1.00000
161   hdd   5.45789         osd.161          up  1.00000 1.00000
162   hdd   5.45789         osd.162          up  1.00000 1.00000
-39               0     host ceph-s16
 -5        29.10687     host ceph-s2
 12   hdd   1.81898         osd.12           up  1.00000 1.00000
 14   hdd   1.81898         osd.14           up  1.00000 1.00000
 15   hdd   1.81898         osd.15           up  1.00000 1.00000
 16   hdd   1.81898         osd.16           up  1.00000 1.00000
 17   hdd   1.81898         osd.17           up  1.00000 1.00000
 21   hdd   7.27699         osd.21           up  1.00000 1.00000
 53   hdd   5.45798         osd.53           up  1.00000 1.00000
119   hdd   7.27698         osd.119          up  1.00000 1.00000
 -7        49.11778     host ceph-s3
 24   hdd   1.81898         osd.24           up  1.00000 1.00000
 25   hdd   1.81898         osd.25           up  1.00000 1.00000
 26   hdd   1.81898         osd.26           up  1.00000 1.00000
 27   hdd   1.81898         osd.27           up  1.00000 1.00000
 28   hdd   1.81898         osd.28           up  1.00000 1.00000
 29   hdd   1.81898         osd.29           up  1.00000 1.00000
 30   hdd   1.81898         osd.30           up  1.00000 1.00000
 31   hdd   1.81898         osd.31           up  1.00000 1.00000
 32   hdd   1.81898         osd.32           up  1.00000 1.00000
 33   hdd   1.81898         osd.33           up  1.00000 1.00000
 34   hdd   1.81898         osd.34           up  1.00000 1.00000
 35   hdd   1.81898         osd.35           up  1.00000 1.00000
 36   hdd   5.45799         osd.36           up  1.00000 1.00000
 37   hdd   5.45799         osd.37           up  1.00000 1.00000
 39   hdd   5.45799         osd.39           up  1.00000 1.00000
 40   hdd   5.45799         osd.40           up  1.00000 1.00000
 41   hdd   5.45799         osd.41           up  1.00000 1.00000
 -9        43.66083     host ceph-s4
 42   hdd   1.81898         osd.42           up  1.00000 1.00000
 43   hdd   1.81898         osd.43           up  1.00000 1.00000
 44   hdd   1.81898         osd.44           up  1.00000 1.00000
 45   hdd   1.81898         osd.45           up  1.00000 1.00000
 46   hdd   1.81898         osd.46           up  1.00000 1.00000
 47   hdd   1.81898         osd.47           up  1.00000 1.00000
 48   hdd   1.81898         osd.48           up  1.00000 1.00000
 49   hdd   1.81898         osd.49           up  1.00000 1.00000
 50   hdd   1.81898         osd.50           up  1.00000 1.00000
 51   hdd   5.45799         osd.51           up  1.00000 1.00000
 52   hdd   5.45799         osd.52           up  1.00000 1.00000
 54   hdd   5.45799         osd.54           up  1.00000 1.00000
 55   hdd   5.45799         osd.55           up  1.00000 1.00000
 56   hdd   5.45799         osd.56           up  1.00000 1.00000
-21        36.38551     host ceph-s5
  7   hdd   7.27699         osd.7            up  1.00000 1.00000
 13   hdd   1.81929         osd.13           up  1.00000 1.00000
 18   hdd   7.27699         osd.18           up  1.00000 1.00000
 57   hdd   1.81929         osd.57           up  1.00000 1.00000
 68   hdd   3.63860         osd.68           up  1.00000 1.00000
 69   hdd   1.81929         osd.69           up  1.00000 1.00000
 70   hdd   1.81929         osd.70           up  0.95000 1.00000
120   hdd   5.45789         osd.120          up  1.00000 1.00000
147   hdd   5.45789         osd.147          up  1.00000 1.00000
-23        45.48241     host ceph-s6
 11   hdd   5.45799         osd.11           up  1.00000 1.00000
 20   hdd   7.27699         osd.20           up  1.00000 1.00000
 71   hdd   1.81929         osd.71           up  1.00000 1.00000
 72   hdd   1.81929         osd.72           up  1.00000 1.00000
 73   hdd   3.63860         osd.73           up  1.00000 1.00000
 74   hdd   1.81929         osd.74           up  1.00000 1.00000
 75   hdd   1.81929         osd.75           up  1.00000 1.00000
116   hdd   7.27730         osd.116          up  1.00000 1.00000
121   hdd   3.63860         osd.121          up  1.00000 1.00000
148   hdd   5.45789         osd.148          up  1.00000 1.00000
149   hdd   5.45789         osd.149          up  1.00000 1.00000
-25        41.84180     host ceph-s7
 19   hdd   7.27699         osd.19           up  1.00000 1.00000
 76   hdd   1.81929         osd.76           up  1.00000 1.00000
 77   hdd   1.81929         osd.77           up  0.95000 1.00000
 78   hdd   1.81929         osd.78           up  1.00000 1.00000
 79   hdd   3.63860         osd.79           up  1.00000 1.00000
 81   hdd   1.81929         osd.81           up  1.00000 1.00000
108   hdd   1.81929         osd.108          up  1.00000 1.00000
140   hdd  10.91399         osd.140          up  1.00000 1.00000
150   hdd   5.45789         osd.150          up  1.00000 1.00000
151   hdd   5.45789         osd.151          up  1.00000 1.00000
-41        27.28761     host ceph-s8
122   hdd   1.81929         osd.122          up  1.00000 1.00000
135   hdd   1.81929         osd.135          up  1.00000 1.00000
136   hdd   1.81929         osd.136          up  1.00000 1.00000
137   hdd   1.81929         osd.137          up  1.00000 1.00000
138   hdd   1.81929         osd.138          up  1.00000 1.00000
139   hdd   1.81929         osd.139          up  1.00000 1.00000
141   hdd  10.91399         osd.141          up  1.00000 1.00000
152   hdd   5.45789         osd.152          up  1.00000 1.00000
-27        43.66139     host ceph-s9
 10   hdd   5.45799         osd.10           up  1.00000 1.00000
 82   hdd   5.45789         osd.82           up  1.00000 1.00000
 83   hdd   1.81929         osd.83           up  1.00000 1.00000
 84   hdd   1.81929         osd.84           up  1.00000 1.00000
 85   hdd   1.81929         osd.85           up  1.00000 1.00000
114   hdd   5.45789         osd.114          up  1.00000 1.00000
123   hdd   5.45789         osd.123          up  1.00000 1.00000
142   hdd  10.91399         osd.142          up  1.00000 1.00000
153   hdd   5.45789         osd.153          up  1.00000 1.00000
144   hdd         0 osd.144                  up  1.00000 1.00000
145   hdd         0 osd.145                  up  1.00000 1.00000
146   hdd         0 osd.146                  up  1.00000 1.00000

our issue lies in very uneven distribution data, where some OSD's have 93% usage and others have 50-60%. I understand that ceph has to replicate and redistribute so that a failure of one node is not a problem, but it still seems quite a bit extreme to me. Due to this, i also find it very hard to calculate how much free space(after replication/erasure coding and all ceph overhead) the cluster has. My question is - is there a way to adjust the replication/erasure coding so our redistribution isn't that skewed? Also, how do i figure out the free space/overhead in this setup? I'm not sure, whether our issue lies in our disk distribution or some of our settings. The ceph osd df output follows:
ID  CLASS WEIGHT   REWEIGHT SIZE   USE   AVAIL %USE  VAR  PGS
 60   hdd  0.09499  1.00000 10240M 2052M 8187M 20.04 0.34   0
 61   hdd  0.09499  1.00000 10240M 2214M 8025M 21.63 0.36   0
 62   hdd  0.09499  1.00000 10240M 2078M 8161M 20.30 0.34   0
 63   hdd  0.09499  1.00000 10240M 2074M 8165M 20.26 0.34   0
 64   hdd  0.09499  1.00000 10240M 1646M 8593M 16.08 0.27   0
 65   hdd  0.09499  1.00000 10240M 2024M 8215M 19.77 0.33   0
 66   hdd  0.09499  1.00000 10240M 2158M 8081M 21.08 0.35   0
 67   hdd  0.09499  1.00000 10240M 2022M 8217M 19.75 0.33   0
  0   hdd  1.81898  1.00000  1862G 1178G  684G 63.28 1.06  47
  1   hdd  1.81898  1.00000  1862G 1228G  634G 65.96 1.10  47
  2   hdd  1.81898  1.00000  1862G 1150G  712G 61.74 1.03  47
  3   hdd  1.81898  1.00000  1862G 1076G  786G 57.81 0.97  42
  4   hdd  1.81898  1.00000  1862G 1027G  835G 55.15 0.92  38
  5   hdd  1.81898  1.00000  1862G 1409G  452G 75.69 1.27  58
 38   hdd  5.45798  1.00000  5588G 3763G 1825G 67.33 1.13 148
113   hdd  7.27698  1.00000  7451G 5070G 2381G 68.04 1.14 208
117   hdd  7.27698  1.00000  7451G 4795G 2656G 64.35 1.08 196
118   hdd  5.45789  1.00000  5588G 3631G 1957G 64.98 1.09 143
 86   hdd  1.81929  1.00000  1862G 1157G  705G 62.14 1.04  45
 87   hdd  1.81929  1.00000  1862G 1379G  483G 74.07 1.24  54
 88   hdd  1.81929  1.00000  1862G 1295G  567G 69.56 1.16  54
 89   hdd  1.81929  1.00000  1862G 1405G  457G 75.47 1.26  56
 90   hdd  1.81929  1.00000  1862G 1399G  463G 75.13 1.26  53
 91   hdd  1.81929  1.00000  1862G 1188G  674G 63.79 1.07  49
115   hdd  5.45789  1.00000  5588G 3750G 1838G 67.10 1.12 151
124   hdd  7.27730  1.00000  7451G 5369G 2082G 72.05 1.20 213
125   hdd  5.45789  1.00000  5588G 3924G 1664G 70.21 1.17 158
154   hdd  5.45789  1.00000  5588G  891G 4697G 15.95 0.27  17
  6   hdd  7.27699  1.00000  7451G 5190G 2261G 69.65 1.16 210
 92   hdd  5.45789  1.00000  5588G 3718G 1870G 66.54 1.11 153
 93   hdd  1.81929  1.00000  1862G 1011G  850G 54.32 0.91  40
 94   hdd  1.81929  1.00000  1862G 1348G  514G 72.38 1.21  55
 95   hdd  1.81929  1.00000  1862G  949G  913G 50.97 0.85  36
100   hdd  7.27730  1.00000  7451G 4271G 3179G 57.33 0.96 171
109   hdd  1.81929  1.00000  1862G 1559G  303G 83.72 1.40  57
110   hdd  1.81929  1.00000  1862G 1096G  766G 58.86 0.98  43
143   hdd 10.91399  1.00000 11175G 7705G 3470G 68.94 1.15 231
155   hdd  5.45789  1.00000  5588G  961G 4627G 17.20 0.29  12
156   hdd  5.45789  1.00000  5588G  819G 4769G 14.66 0.25  10
  8   hdd  1.81929  1.00000  1862G 1600G  262G 85.91 1.44  62
  9   hdd  1.81929  1.00000  1862G 1656G  206G 88.90 1.49  64
 23   hdd  5.45799  1.00000  5588G 5045G  543G 90.27 1.51 169
 58   hdd  1.81929  1.00000  1862G 1592G  270G 85.49 1.43  64
 59   hdd  3.63860  1.00000  3725G 3034G  691G 81.44 1.36 117
 80   hdd  1.81929  1.00000  1862G 1684G  178G 90.43 1.51  62
 96   hdd  1.81929  1.00000  1862G 1418G  444G 76.16 1.27  56
111   hdd  2.72890  1.00000  2794G 2037G  756G 72.92 1.22  79
126   hdd  5.45789  1.00000  5588G 4891G  697G 87.52 1.46 192
157   hdd  5.45789  1.00000  5588G  929G 4659G 16.63 0.28  10
158   hdd  5.45789  1.00000  5588G 1078G 4510G 19.30 0.32  12
 97   hdd  1.81929  1.00000  1862G 1219G  643G 65.47 1.09  50
 98   hdd  1.81929  1.00000  1862G 1289G  573G 69.21 1.16  50
 99   hdd  1.81929  1.00000  1862G 1489G  373G 79.93 1.34  59
101   hdd  1.81929  1.00000  1862G 1498G  364G 80.46 1.35  59
107   hdd  1.81929  1.00000  1862G 1666G  196G 89.44 1.50  62
112   hdd  1.81929  1.00000  1862G 1607G  255G 86.27 1.44  68
127   hdd  7.27730  1.00000  7451G 5542G 1909G 74.37 1.24 222
128   hdd  3.63860  1.00000  3725G 2724G 1001G 73.13 1.22 103
129   hdd  3.63860  1.00000  3725G 3278G  447G 88.00 1.47 129
130   hdd  3.63860  1.00000  3725G 2818G  907G 75.64 1.26 113
133   hdd  3.63860  1.00000  3725G 3413G  312G 91.60 1.53 128
159   hdd  5.45789  1.00000  5588G  886G 4702G 15.86 0.27  13
160   hdd  5.45789  1.00000  5588G  868G 4720G 15.54 0.26  10
 22   hdd  5.45799  1.00000  5588G 4227G 1361G 75.64 1.27 166
102   hdd  1.81929  1.00000  1862G 1438G  424G 77.20 1.29  55
103   hdd  5.45789  1.00000  5588G 4773G  815G 85.40 1.43 184
104   hdd  1.81929  1.00000  1862G 1476G  385G 79.28 1.33  58
105   hdd  1.81929  1.00000  1862G 1649G  213G 88.53 1.48  63
106   hdd  5.45789  1.00000  5588G 4870G  718G 87.14 1.46 172
131   hdd  3.63860  1.00000  3725G 2884G  841G 77.41 1.29 110
132   hdd  3.63860  1.00000  3725G 2937G  787G 78.85 1.32 113
134   hdd  3.63860  1.00000  3725G 3421G  304G 91.84 1.54 116
161   hdd  5.45789  1.00000  5588G  741G 4847G 13.26 0.22  13
162   hdd  5.45789  1.00000  5588G  922G 4666G 16.50 0.28  16
 12   hdd  1.81898  1.00000  1862G 1049G  813G 56.35 0.94  41
 14   hdd  1.81898  1.00000  1862G 1568G  294G 84.19 1.41  63
 15   hdd  1.81898  1.00000  1862G 1654G  208G 88.80 1.49  66
 16   hdd  1.81898  1.00000  1862G 1210G  652G 64.97 1.09  49
 17   hdd  1.81898  1.00000  1862G 1360G  502G 73.03 1.22  53
 21   hdd  7.27699  1.00000  7451G 5414G 2037G 72.66 1.22 189
 53   hdd  5.45798  1.00000  5588G 4083G 1505G 73.06 1.22 167
119   hdd  7.27698  1.00000  7451G 5557G 1894G 74.57 1.25 224
 24   hdd  1.81898  1.00000  1862G  847G 1015G 45.47 0.76  35
 25   hdd  1.81898  1.00000  1862G  960G  902G 51.53 0.86  39
 26   hdd  1.81898  1.00000  1862G  916G  946G 49.22 0.82  38
 27   hdd  1.81898  1.00000  1862G 1117G  745G 60.00 1.00  47
 28   hdd  1.81898  1.00000  1862G 1266G  596G 68.00 1.14  52
 29   hdd  1.81898  1.00000  1862G  849G 1013G 45.60 0.76  33
 30   hdd  1.81898  1.00000  1862G 1159G  703G 62.25 1.04  46
 31   hdd  1.81898  1.00000  1862G  990G  872G 53.18 0.89  41
 32   hdd  1.81898  1.00000  1862G 1086G  776G 58.31 0.98  43
 33   hdd  1.81898  1.00000  1862G 1027G  835G 55.13 0.92  41
 34   hdd  1.81898  1.00000  1862G 1075G  787G 57.75 0.97  45
 35   hdd  1.81898  1.00000  1862G  895G  967G 48.08 0.80  37
 36   hdd  5.45799  1.00000  5588G 2789G 2799G 49.92 0.83 106
 37   hdd  5.45799  1.00000  5588G 2963G 2625G 53.02 0.89 120
 39   hdd  5.45799  1.00000  5588G 3271G 2317G 58.54 0.98 129
 40   hdd  5.45799  1.00000  5588G 3640G 1948G 65.13 1.09 148
 41   hdd  5.45799  1.00000  5588G 3099G 2489G 55.45 0.93 130
 42   hdd  1.81898  1.00000  1862G 1093G  769G 58.71 0.98  46
 43   hdd  1.81898  1.00000  1862G  896G  966G 48.14 0.81  34
 44   hdd  1.81898  1.00000  1862G 1226G  636G 65.85 1.10  50
 45   hdd  1.81898  1.00000  1862G  982G  880G 52.73 0.88  37
 46   hdd  1.81898  1.00000  1862G  998G  864G 53.60 0.90  39
 47   hdd  1.81898  1.00000  1862G 1234G  628G 66.28 1.11  48
 48   hdd  1.81898  1.00000  1862G  963G  899G 51.74 0.87  41
 49   hdd  1.81898  1.00000  1862G 1404G  458G 75.38 1.26  57
 50   hdd  1.81898  1.00000  1862G 1232G  630G 66.15 1.11  50
 51   hdd  5.45799  1.00000  5588G 3110G 2478G 55.66 0.93 127
 52   hdd  5.45799  1.00000  5588G 3058G 2530G 54.73 0.92 120
 54   hdd  5.45799  1.00000  5588G 3293G 2295G 58.92 0.99 130
 55   hdd  5.45799  1.00000  5588G 3407G 2181G 60.97 1.02 136
 56   hdd  5.45799  1.00000  5588G 3304G 2284G 59.12 0.99 133
  7   hdd  7.27699  1.00000  7451G 5820G 1631G 78.11 1.31 222
 13   hdd  1.81929  1.00000  1862G 1433G  429G 76.95 1.29  56
 18   hdd  7.27699  1.00000  7451G 5001G 2450G 67.11 1.12 165
 57   hdd  1.81929  1.00000  1862G 1269G  593G 68.15 1.14  51
 68   hdd  3.63860  1.00000  3725G 2906G  819G 78.01 1.30 119
 69   hdd  1.81929  1.00000  1862G 1316G  546G 70.66 1.18  53
 70   hdd  1.81929  0.95000  1862G 1224G  638G 65.73 1.10  49
120   hdd  5.45789  1.00000  5588G 3900G 1687G 69.80 1.17 151
147   hdd  5.45789  1.00000  5588G  869G 4719G 15.56 0.26   8
 11   hdd  5.45799  1.00000  5588G 4174G 1414G 74.70 1.25 162
 20   hdd  7.27699  1.00000  7451G 5430G 2021G 72.88 1.22 221
 71   hdd  1.81929  1.00000  1862G 1300G  562G 69.83 1.17  55
 72   hdd  1.81929  1.00000  1862G 1093G  769G 58.70 0.98  44
 73   hdd  3.63860  1.00000  3725G 2706G 1019G 72.63 1.21 112
 74   hdd  1.81929  1.00000  1862G 1295G  567G 69.54 1.16  50
 75   hdd  1.81929  1.00000  1862G 1127G  735G 60.53 1.01  45
116   hdd  7.27730  1.00000  7451G 4775G 2676G 64.09 1.07 181
121   hdd  3.63860  1.00000  3725G 2163G 1562G 58.06 0.97  84
148   hdd  5.45789  1.00000  5588G  832G 4756G 14.90 0.25  14
149   hdd  5.45789  1.00000  5588G  776G 4812G 13.89 0.23  13
 19   hdd  7.27699  1.00000  7451G 5664G 1787G 76.01 1.27 206
 76   hdd  1.81929  1.00000  1862G 1476G  386G 79.26 1.33  59
 77   hdd  1.81929  0.95000  1862G 1513G  349G 81.24 1.36  60
 78   hdd  1.81929  1.00000  1862G 1503G  359G 80.70 1.35  65
 79   hdd  3.63860  1.00000  3725G 2705G 1020G 72.62 1.21 104
 81   hdd  1.81929  1.00000  1862G 1315G  547G 70.63 1.18  50
108   hdd  1.81929  1.00000  1862G 1706G  156G 91.59 1.53  61
140   hdd 10.91399  1.00000 11175G 8090G 3085G 72.39 1.21 313
150   hdd  5.45789  1.00000  5588G  939G 4649G 16.81 0.28  16
151   hdd  5.45789  1.00000  5588G  900G 4688G 16.10 0.27  12
122   hdd  1.81929  1.00000  1862G 1731G  131G 92.93 1.55  73
135   hdd  1.81929  1.00000  1862G 1605G  256G 86.21 1.44  65
136   hdd  1.81929  1.00000  1862G 1441G  421G 77.36 1.29  58
137   hdd  1.81929  1.00000  1862G 1693G  169G 90.93 1.52  70
138   hdd  1.81929  1.00000  1862G 1275G  587G 68.46 1.14  49
139   hdd  1.81929  1.00000  1862G 1705G  157G 91.54 1.53  66
141   hdd 10.91399  1.00000 11175G 8657G 2518G 77.47 1.30 299
152   hdd  5.45789  1.00000  5588G  999G 4589G 17.88 0.30  11
 10   hdd  5.45799  1.00000  5588G 3825G 1763G 68.45 1.14 156
 82   hdd  5.45789  1.00000  5588G 3839G 1749G 68.69 1.15 152
 83   hdd  1.81929  1.00000  1862G 1231G  631G 66.11 1.11  49
 84   hdd  1.81929  1.00000  1862G 1273G  589G 68.37 1.14  49
 85   hdd  1.81929  1.00000  1862G 1429G  432G 76.76 1.28  59
114   hdd  5.45789  1.00000  5588G 3455G 2133G 61.83 1.03 138
123   hdd  5.45789  1.00000  5588G 3678G 1910G 65.82 1.10 146
142   hdd 10.91399  1.00000 11175G 7359G 3816G 65.85 1.10 298
153   hdd  5.45789  1.00000  5588G  986G 4602G 17.64 0.30  17
144   hdd        0  1.00000  5588G 1454M 5587G  0.03    0   0
145   hdd        0  1.00000  5588G 1446M 5587G  0.03    0   0
146   hdd        0  1.00000  5588G 1455M 5587G  0.03    0   0
                      TOTAL   579T  346T  232T 59.80
MIN/MAX VAR: 0/1.55  STDDEV: 23.04

THanks in advance for any help, i find it very hard to wrap my head around this.