On 29.03.2018 10:25, ST Wong (ITSC) wrote: > While servers in each building have alternate uplinks. What will > happen in case the link between the buildings is broken (application > servers in each server room will continue to write to OSDs in the same > room) ? The side with the lesser number of monitors will stop working. Applications will not be able to write or read any more as the monitors still reachable in their network will have no quorum and refuse to give out the cluster map. Regards -- Robert Sander Heinlein Support GmbH Schwedter Str. 8/9b, 10119 Berlin http://www.heinlein-support.de Tel: 030 / 405051-43 Fax: 030 / 405051-19 Zwangsangaben lt. §35a GmbHG: HRB 93818 B / Amtsgericht Berlin-Charlottenburg, Geschäftsführer: Peer Heinlein -- Sitz: Berlin