Re: Full Ratio

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

if you are using an older Ceph version note that the mon_osd_near_full_ration and mon_osd_full_ration must be set in the config file on the MON hosts first and then the MONs restarted one after the other one.

If using a recent  version there is a command ceph osd set-full-ratio and ceph osd set-nearfull-ratio

Regards
JC

> On Jan 24, 2018, at 11:07, Karun Josy <karunjosy1@xxxxxxxxx> wrote:
> 
> Hi,
> 
> I am trying to increase the full ratio of OSDs in a cluster.
> While adding a new node one of the new disk got backfilled to more than 95% and cluster freezed. So I am trying to avoid it from happening again.
> 
> 
> Tried pg set command but it is not working : 
> $ ceph pg set_nearfull_ratio 0.88
> Error ENOTSUP: this command is obsolete
> 
> I had increased the full ratio in osds using injectargs initially but it didnt work as when the disk reached 95% it showed osd full status
> 
> $ ceph tell osd.* injectargs '--mon_osd_full_ratio 0.97'
> osd.0: mon_osd_full_ratio = '0.970000' (not observed, change may require restart)
> osd.1: mon_osd_full_ratio = '0.970000' (not observed, change may require restart)
> ----
> ----
> 
> How can I set full ratio to more than 95% ? 
> 
> Karun 
> _______________________________________________
> ceph-users mailing list
> ceph-users@xxxxxxxxxxxxxx
> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com