Needed help to setup a 3-way replication between 2 datacenters

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi everyone,

Beginner with Ceph, i’m looking for a way to do a 3-way replication between 2 datacenters as mention in ceph docs (but not describe).

My goal is to keep access to the data (at least read-only access) even when the link between the 2 datacenters is cut and make sure at least one copy of the data exists in each datacenter.

I’m not sure how to implement such 3-way replication. With a rule?
Based on the CEPH docs, I think of a rule:
rule 3-way-replication_with_2_DC {
ruleset 1
type replicated
min_size 2
max_size 3
step take DC-1
step choose firstn 1 type host
step chooseleaf firstn 1 type osd
step emit
step take DC-2
step choose firstn 1 type host
step chooseleaf firstn 1 type osd
step emit
step take default
step choose firstn 1 type host
step chooseleaf firstn 1 type osd
step emit
}
but what should happen if the link between the 2 datacenters is cut? If someone has a better solution, I interested by any resources about it (examples, …).

The default rule (see below) keep the pool working when we mark each node of DC-2 as down (typically maintenance) but if we shut the link down between the 2 datacenters, the pool/rbd hangs (frozen writing dd tool for example).
Does anyone have some insight on how to setup a 3-way replication between 2 datacenters?

Thanks in advance for any advice on the topic.

Current situation:

Mons : host-1, host-2, host-4

Quick network topology:

USERS NETWORK
     |
   2x10G
     |
  DC-1-SWITCH <——— 40G ——> DC-2-SWITCH
        | | |                   | | |
host-1 _| | |           host-4 _| | |
host-2 ___| |           host-5 ___| |
host-3 _____|           host-6 _____|



crushmap :
# ceph osd tree
ID  CLASS WEIGHT    TYPE NAME                   STATUS REWEIGHT PRI-AFF
 -1       147.33325 root default
-20        73.66663     datacenter DC-1
-15        73.66663         rack DC-1-RACK-1
 -9        24.55554             host host-1
 27   hdd   2.72839                 osd.27          up  1.00000 1.00000
 28   hdd   2.72839                 osd.28          up  1.00000 1.00000
 29   hdd   2.72839                 osd.29          up  1.00000 1.00000
 30   hdd   2.72839                 osd.30          up  1.00000 1.00000
 31   hdd   2.72839                 osd.31          up  1.00000 1.00000
 32   hdd   2.72839                 osd.32          up  1.00000 1.00000
 33   hdd   2.72839                 osd.33          up  1.00000 1.00000
 34   hdd   2.72839                 osd.34          up  1.00000 1.00000
 36   hdd   2.72839                 osd.36          up  1.00000 1.00000
-11        24.55554             host host-2
 35   hdd   2.72839                 osd.35          up  1.00000 1.00000
 37   hdd   2.72839                 osd.37          up  1.00000 1.00000
 38   hdd   2.72839                 osd.38          up  1.00000 1.00000
 39   hdd   2.72839                 osd.39          up  1.00000 1.00000
 40   hdd   2.72839                 osd.40          up  1.00000 1.00000
 41   hdd   2.72839                 osd.41          up  1.00000 1.00000
 42   hdd   2.72839                 osd.42          up  1.00000 1.00000
 43   hdd   2.72839                 osd.43          up  1.00000 1.00000
 46   hdd   2.72839                 osd.46          up  1.00000 1.00000
-13        24.55554             host host-3
 44   hdd   2.72839                 osd.44          up  1.00000 1.00000
 45   hdd   2.72839                 osd.45          up  1.00000 1.00000
 47   hdd   2.72839                 osd.47          up  1.00000 1.00000
 48   hdd   2.72839                 osd.48          up  1.00000 1.00000
 49   hdd   2.72839                 osd.49          up  1.00000 1.00000
 50   hdd   2.72839                 osd.50          up  1.00000 1.00000
 51   hdd   2.72839                 osd.51          up  1.00000 1.00000
 52   hdd   2.72839                 osd.52          up  1.00000 1.00000
 53   hdd   2.72839                 osd.53          up  1.00000 1.00000
-19        73.66663     datacenter DC-2
-16        73.66663         rack DC-2-RACK-1
 -3        24.55554             host host-4
  0   hdd   2.72839                 osd.0           up  1.00000 1.00000
  1   hdd   2.72839                 osd.1           up  1.00000 1.00000
  2   hdd   2.72839                 osd.2           up  1.00000 1.00000
  3   hdd   2.72839                 osd.3           up  1.00000 1.00000
  4   hdd   2.72839                 osd.4           up  1.00000 1.00000
  5   hdd   2.72839                 osd.5           up  1.00000 1.00000
  6   hdd   2.72839                 osd.6           up  1.00000 1.00000
  7   hdd   2.72839                 osd.7           up  1.00000 1.00000
  8   hdd   2.72839                 osd.8           up  1.00000 1.00000
 -5        24.55554             host host-5
  9   hdd   2.72839                 osd.9           up  1.00000 1.00000
 10   hdd   2.72839                 osd.10          up  1.00000 1.00000
 11   hdd   2.72839                 osd.11          up  1.00000 1.00000
 12   hdd   2.72839                 osd.12          up  1.00000 1.00000
 13   hdd   2.72839                 osd.13          up  1.00000 1.00000
 14   hdd   2.72839                 osd.14          up  1.00000 1.00000
 15   hdd   2.72839                 osd.15          up  1.00000 1.00000
 16   hdd   2.72839                 osd.16          up  1.00000 1.00000
 18   hdd   2.72839                 osd.18          up  1.00000 1.00000
 -7        24.55554             host host-6
 19   hdd   2.72839                 osd.19          up  1.00000 1.00000
 20   hdd   2.72839                 osd.20          up  1.00000 1.00000
 21   hdd   2.72839                 osd.21          up  1.00000 1.00000
 22   hdd   2.72839                 osd.22          up  1.00000 1.00000
 23   hdd   2.72839                 osd.23          up  1.00000 1.00000
 24   hdd   2.72839                 osd.24          up  1.00000 1.00000
 25   hdd   2.72839                 osd.25          up  1.00000 1.00000
 26   hdd   2.72839                 osd.26          up  1.00000 1.00000
 54   hdd   2.72839                 osd.54          up  1.00000 1.00000

current rules (default one) :
# ceph osd crush rule dump
[
    {
        "rule_id": 0,
        "rule_name": "replicated_rule",
        "ruleset": 0,
        "type": 1,
        "min_size": 1,
        "max_size": 10,
        "steps": [
            {
                "op": "take",
                "item": -1,
                "item_name": "default"
            },
            {
                "op": "chooseleaf_firstn",
                "num": 0,
                "type": "host"
            },
            {
                "op": "emit"
            }
        ]
    }
]

Cordialement / Best regards,

Sébastien VIGNERON 
CRIANN, 
Ingénieur / Engineer
Technopôle du Madrillet 
745, avenue de l'Université 
76800 Saint-Etienne du Rouvray - France 
tél. +33 2 32 91 42 91 
fax. +33 2 32 91 42 92 
http://www.criann.fr 
mailto:sebastien.vigneron@xxxxxxxxx
support: support@xxxxxxxxx

_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]


  Powered by Linux