The OSD needs to be marked as "out" before data movement will occur. This is to give it a chance to come back in.
--
By default as seen in config_opts.h (linked to in one of your other recent threads), an OSD should be marked out 300 seconds after going down if it isn't marked back up before then. You can adjust osd_down_out_interval as desired. It looks like it's been defaulted to 600s in newer versions.
On Thu, Dec 22, 2016 at 2:54 AM, Stéphane Klein <contact@xxxxxxxxxxxxxxxxxxx> wrote:
StéphaneHi,Best regards,
How can I ask to Ceph Cluster to move blocks now when osd is down?--Stéphane Klein <contact@xxxxxxxxxxxxxxxxxxx>
blog: http://stephane-klein.info
cv : http://cv.stephane-klein.info
Twitter: http://twitter.com/klein_stephane
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph. com
Brian Andrus
Cloud Systems Engineer
DreamHost, LLC
_______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com