For redundancy I would suggest bonding the interfaces using LACP that way both ports are combined under the same interface with the same IP. They will both send and receive traffic and if one link goes down the other continues to work. The ports will need to be configured for LACP on the switch as well.
___
John Petrini
NOC Systems Administrator // CoreDial, LLC // coredial.com //
Hillcrest I, 751 Arbor Way, Suite 150, Blue Bell PA, 19422
P: 215.297.4400 x232 // F: 215.297.4401 // E: jpetrini@xxxxxxxxxxxx
The information transmitted is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material. Any review, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the sender and delete the material from any computer.
On Wed, Nov 30, 2016 at 12:15 PM, Mike Jacobacci <mikej@xxxxxxxxxx> wrote:
I ran into an interesting issue last night when I tried to add a second storage interface. The original 10gb storage interface on the OSD node was only set at 1500 MTU, so the plan was to bump it to 9000 and configure the second interface the same way with a diff IP and reboot. Once I did that, for some reason the original interface showed active but would not respond to ping from the other OSD nodes, the second interface I added came up and was reachable. So even though the node could still communicate to the others on the second interface, PG's would start remapping and would get stuck at about 300 (of 1024). I resolved the issue by changing the config back on the original interface and disabling the second. After a Reboot, PG's recovered very quickly.It seemed that the remapping would only go partially because the first node could reach the others, but they couldn't reach the original interface and didn't use the newly added second. So for my questions:Is there a proper way to add an additional interface (for redundancy) to the storage network so that it's recognized by the cluster?If IPV6 is enabled on a storage interface when the cluster was created, would it be a problem to disable it now?Cheers,Mike
_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph. com
_______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com