> Op 11 augustus 2016 om 15:17 schreef Sean Sullivan <seapasulli@xxxxxxxxxxxx>: > > > Hello Wido, > > Thanks for the advice. While the data center has a/b circuits and > redundant power, etc if a ground fault happens it travels outside and > fails causing the whole building to fail (apparently). > > The monitors are each the same with > 2x e5 cpus > 64gb of ram > 4x 300gb 10k SAS drives in raid 10 (write through mode). > Ubuntu 14.04 with the latest updates prior to power failure (2016/Aug/10 - > 3am CST) > Ceph hammer LTS 0.94.7 > > (we are still working on our jewel test cluster so it is planned but not in > place yet) > > The only thing that seems to be corrupt is the monitors leveldb store. I > see multiple issues on Google leveldb github from March 2016 about fsync > and power failure so I assume this is an issue with leveldb. > > I have backed up /var/lib/ceph/Mon on all of my monitors before trying to > proceed with any form of recovery. > > Is there any way to reconstruct the leveldb or replace the monitors and > recover the data? > I don't know. I have never done it. Other people might know this better than me. Maybe 'ceph-monstore-tool' can help you? Wido > I found the following post in which sage says it is tedious but possible. ( > http://www.spinics.net/lists/ceph-devel/msg06662.html). Tedious is fine if > I have any chance of doing it. I have the fsid, the Mon key map and all of > the osds look to be fine so all of the previous osd maps are there. > > I just don't understand what key/values I need inside. > > On Aug 11, 2016 1:33 AM, "Wido den Hollander" <wido@xxxxxxxx> wrote: > > > > > > Op 11 augustus 2016 om 0:10 schreef Sean Sullivan < > > seapasulli@xxxxxxxxxxxx>: > > > > > > > > > I think it just got worse:: > > > > > > all three monitors on my other cluster say that ceph-mon can't open > > > /var/lib/ceph/mon/$(hostname). Is there any way to recover if you lose > > all > > > 3 monitors? I saw a post by Sage saying that the data can be recovered as > > > all of the data is held on other servers. Is this possible? If so has > > > anyone had any experience doing so? > > > > I have never done so, so I couldn't tell you. > > > > However, it is weird that on all three it got corrupted. What hardware are > > you using? Was it properly protected against power failure? > > > > If you mon store is corrupted I'm not sure what might happen. > > > > However, make a backup of ALL monitors right now before doing anything. > > > > Wido > > > > > _______________________________________________ > > > ceph-users mailing list > > > ceph-users@xxxxxxxxxxxxxx > > > http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com > > _______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com