Hi everyone,
we see at our cluster relatively slow Single Thread Performance on the
iscsi Nodes.
Our setup:
3 Racks:
18x Data Nodes, 3 Mon Nodes, 3 iscsi Gateway Nodes with tgt (rbd cache off).
2x Samsung SM863 Enterprise SSD for Journal (3 OSD per SSD) and 6x WD
Red 1TB per Data Node as OSD.
Replication = 3
chooseleaf = 3 type Rack in the crush map
We get only ca. 90 MByte/s on the iscsi Gateway Servers with:
rados bench -p rbd 60 write -b 4M -t 1
If we test with:
rados bench -p rbd 60 write -b 4M -t 32
we get ca. 600 - 700 MByte/s
We plan to replace the Samsung SSD with Intel DC P3700 PCIe NVM'e for
the Journal to get better Single Thread Performance.
Is anyone of you out there who has an Intel P3700 for Journal an can
give me back test results with:
rados bench -p rbd 60 write -b 4M -t 1
Thank you very much !!
Kind Regards !!