Re: Maximum MON Network Throughput Requirements

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Mons and RGWs only use the public network but Mons can have a good deal of traffic. I would not recommend 1Gb but if looking for lower bandwidth then 10Gb would be good for most. It all depends in the overall size of the cluster. You mentioned 40Gb. If the nodes are high density then 40Gb but if they are lower density then 20Gb would be fine.

-CJ

On Mon, May 2, 2016 at 12:09 PM, Brady Deetz <bdeetz@xxxxxxxxx> wrote:
I'm working on finalizing designs for my Ceph deployment. I'm currently leaning toward 40gbps ethernet for interconnect between OSD nodes and to my MDS servers. But, I don't really want to run 40 gig to my mon servers unless there is a reason. Would there be an issue with using 1 gig on my monitor servers?

_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com




--
Best Regards,
Chris Jones

(p) 770.655.0770

_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com