Hi,
I have a setup with two MDS in active/standby configuration. During
times of high network load / network congestion, the active MDS is
bounced between both instances:
1. mons(?) decide that MDS A is crashed/not available due to missing
heartbeats
2015-12-15 16:38:08.471608 7f880df10700 1 mds.beacon.ceph-storage-01
_send skipping beacon, heartbeat map not healthy
2015-12-15 16:38:10.534941 7f8813e4b700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
...
2015-12-15 16:38:15.468190 7f880e711700 1 heartbeat_map reset_timeout
'MDS' had timed out after 15
2015-12-15 16:38:17.734172 7f8811818700 1 mds.-1.-1 handle_mds_map i
(192.168.6.129:6825/2846) dne in the mdsmap, respawning myself
2. Failover to standby MDS B
3. MDS B starts recover/rejoin (takes up to 15 minutes), introducing
even more load
4. MDS A is respawned as new standby MDS
5. mons kick out MDS B after timeout
6. Failover to MDS A
....
I resolve this situation by shutting down one MDS completely and force
the cluster to use the remaining one:
2015-12-15 16:40:20.618774 7f7ca6946700 1 mds.0.80 reconnect_done
2015-12-15 16:40:25.815374 7f7ca6946700 1 mds.0.80 handle_mds_map i am
now mds.0.80
2015-12-15 16:40:25.815384 7f7ca6946700 1 mds.0.80 handle_mds_map state
change up:reconnect --> up:rejoin
2015-12-15 16:40:25.815388 7f7ca6946700 1 mds.0.80 rejoin_start
2015-12-15 16:40:43.159921 7f7ca894a700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
2015-12-15 16:40:44.619252 7f7ca303e700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
2015-12-15 16:40:44.619260 7f7ca303e700 1 mds.beacon.cb-dell-pe620r
_send skipping beacon, heartbeat map not healthy
2015-12-15 16:40:48.160055 7f7ca894a700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
2015-12-15 16:40:48.619315 7f7ca303e700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
2015-12-15 16:40:48.619322 7f7ca303e700 1 mds.beacon.cb-dell-pe620r
_send skipping beacon, heartbeat map not healthy
2015-12-15 16:40:52.619380 7f7ca303e700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
2015-12-15 16:40:52.619405 7f7ca303e700 1 mds.beacon.cb-dell-pe620r
_send skipping beacon, heartbeat map not healthy
2015-12-15 16:40:53.160157 7f7ca894a700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
2015-12-15 16:40:56.619442 7f7ca303e700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
2015-12-15 16:40:56.619452 7f7ca303e700 1 mds.beacon.cb-dell-pe620r
_send skipping beacon, heartbeat map not healthy
2015-12-15 16:40:58.160257 7f7ca894a700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
2015-12-15 16:41:00.619510 7f7ca303e700 1 heartbeat_map is_healthy
'MDS' had timed out after 15
2015-12-15 16:41:00.619519 7f7ca303e700 1 mds.beacon.cb-dell-pe620r
_send skipping beacon, heartbeat map not healthy
2015-12-15 16:41:01.339416 7f7ca6946700 1 mds.0.80 rejoin_joint_start
2015-12-15 16:41:01.343018 7f7ca383f700 1 heartbeat_map reset_timeout
'MDS' had timed out after 15
2015-12-15 16:41:05.756154 7f7ca6946700 0 mds.beacon.cb-dell-pe620r
handle_mds_beacon no longer laggy
2015-12-15 16:51:39.648189 7f7ca283d700 1 mds.0.80 rejoin_done
2015-12-15 16:51:40.932766 7f7ca6946700 1 mds.0.80 handle_mds_map i am
now mds.0.80
2015-12-15 16:51:40.932783 7f7ca6946700 1 mds.0.80 handle_mds_map state
change up:rejoin --> up:active
2015-12-15 16:51:40.932788 7f7ca6946700 1 mds.0.80 recovery_done --
successful recovery!
2015-12-15 16:51:43.235230 7f7ca6946700 1 mds.0.80 active_start
2015-12-15 16:51:43.279305 7f7ca6946700 1 mds.0.80 cluster recovered.
...
How do I prevent the mons from removing the active MDS from the mdsmap
or allow a larger timeout? The documentation mentions mds_beacon_grace
and mds_beacon_interval, but it is not clear how these correlate to the
timeouts.
How do I have to change the configuration to allow network congestions
of up to 5 minutes?
Best regards,
Burkhard