Re: CephFs - Ceph-fuse Client Read Performance During Cache Tier Flushing

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi all

The issue is resolved after upgrading Ceph from Giant to Hammer(0.94.1)

cheers
K.Mohamed Pakkeer

On Sun, Apr 26, 2015 at 11:28 AM, Mohamed Pakkeer <mdfakkeer@xxxxxxxxx> wrote:

Hi

 I was doing some testing on erasure coded based CephFS cluster. cluster is running with giant 0.87.1 release.

 

Cluster info

15 * 36 drives node(journal on same osd)

3 * 4 drives SSD cache node( Intel DC3500)

3 * MON/MDS

EC 10 +3

10G Ethernet for private and cluster network

 

We got approx. 55MB/s read transfer speed using ceph-fuse client, when the data was available on cache tier( cold storage was empty). When I tried to add more data, ceph started the flushing the data from cache tier to cold storage. During flushing, cluster read speed became approx 100 KB/s. But I got 50 – 55MB/s write transfer speed during flushing from multiple simultaneous ceph-fuse client( 1G Ethernet). I think there is an issue on data migration from cold storage to cache tier during ceph-fuse client read. Am I hitting any known issue/bug or is there any issue with my cluster?

 

I used big video files( approx 5 GB to 10 GB) for this testing .

 

Any help ?


Cheers   
K.Mohamed Pakkeer





--
Thanks & Regards   
K.Mohamed Pakkeer
Mobile- 0091-8754410114

_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Ceph Dev]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]