Whatever the version you tested, ceph won't recover data when you manually stop osd immediately. And it will trigger mark down osd out when it reach "mon_osd_down_out_interval" seconds. On Tue, Apr 7, 2015 at 8:33 PM, lijian <blacker1981@xxxxxxx> wrote: > Hi, > The recovering start delay 300s after I stop a osd and the osd status change > from in to out, the test ENV is Ceph 0.80.7 > > But I test in ceph 0.87.1, the recovering start immediately after I stop a > OSD,all the settings is the default value,the following is mon_osd* settings > in my test ENV: > "mon_osd_laggy_halflife": "3600", > "mon_osd_laggy_weight": "0.3", > "mon_osd_adjust_heartbeat_grace": "true", > "mon_osd_adjust_down_out_interval": "true", > "mon_osd_auto_mark_in": "false", > "mon_osd_auto_mark_auto_out_in": "true", > "mon_osd_auto_mark_new_in": "true", > "mon_osd_down_out_interval": "300", > "mon_osd_down_out_subtree_limit": "rack", > "mon_osd_min_up_ratio": "0.3", > "mon_osd_min_in_ratio": "0.3", > "mon_osd_max_op_age": "32", > "mon_osd_max_split_count": "32", > "mon_osd_allow_primary_temp": "false", > "mon_osd_allow_primary_affinity": "false", > "mon_osd_full_ratio": "0.95", > "mon_osd_nearfull_ratio": "0.85", > "mon_osd_report_timeout": "45000", > "mon_osd_min_down_reporters": "50", > "mon_osd_min_down_reports": "150", > "mon_osd_force_trim_to": "0", > > so when the recovering start? why they are different with the two Ceph > version, or someting wrong with my settings > > Thanks! > Jian Li > > > > _______________________________________________ > ceph-users mailing list > ceph-users@xxxxxxxxxxxxxx > http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com > -- Best Regards, Wheat _______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com