On 07/06/2014 02:42 PM, Lazuardi Nasution wrote: > Hi, > > Is it possible to combine MDS and MON or OSD inside the same node? Which > one is better, MON with MDS or OSD with MDS? > Yes, not a problem. Be aware, the MDS can be memory hungry depending on your active data set. There is no golden rule for mixing daemons however. CephFS is not stable yet however, keep that in mind! > How do I configure OSD and MDS to allow two kind of public network > connections, standard (1 GbEs) and jumbo (10 GbEs). I want to take > advantage of jumbo frame for some supported clients. That's not possible. There can only be one public network, so your idea is not feasible. > > Best regards, > > > > _______________________________________________ > ceph-users mailing list > ceph-users at lists.ceph.com > http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com > -- Wido den Hollander 42on B.V. Ceph trainer and consultant Phone: +31 (0)20 700 9902 Skype: contact42on