Re: Empty osd and crushmap after mon restart?

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Some guesses are inline.

On Tue, Jun 25, 2013 at 4:06 PM, Wido den Hollander <wido@xxxxxxxx> wrote:
> Hi,
>
> I'm not sure what happened, but on a Ceph cluster I noticed that the
> monitors (running 0.61) started filling up the disks, so they were restarted
> with:
>
> mon compact on start = true
>
> After a restart the osdmap was empty, it showed:
>
>    osdmap e2: 0 osds: 0 up, 0 in
>     pgmap v624077: 15296 pgs: 15296 stale+active+clean; 78104 MB data, 243
> GB used, 66789 GB / 67032 GB avail
>    mdsmap e1: 0/0/1 up
>
> This cluster has 36 OSDs over 9 hosts, but suddenly that was all gone.
>
> I also checked the crushmap, all 36 OSDs were removed, no trace of them.

As you guess, this is probably because the disks filled up. It
shouldn't be able to happen but we found an edge case where leveldb
falls apart; there's a fix for it in the repository now (asserting
that we get back what we just wrote) that Sage can talk more about.
Probably both disappeared because the monitor got nothing back when
reading in the newest OSD Map, and so it's all empty.

> "ceph auth list" still showed their keys though.
>
> Restarting the OSDs didn't help, since create-or-move complained that the
> OSDs didn't exist and didn't do anything. I ran "ceph osd create" to get the
> 36 OSDs created again, but when the OSDs boot they never start working.
>
> The only thing they log is:
>
> 2013-06-26 01:00:08.852410 7f17f3f16700  0 -- 0.0.0.0:6801/4767 >>
> 10.23.24.53:6801/1758 pipe(0x1025fc80 sd=116 :40516 s=1 pgs=0 cs=0
> l=0).fault with nothing to send, going to standby

Are they going up and just sitting idle? This is probably because none
of their peers are telling them to be responsible for any placement
groups on startup.

> The internet connection I'm behind is a 3G connection, so I can't go
> skimming through the logs with debugging at very high levels, but I'm just
> wondering what this could be?
>
> It's obvious that the monitors filling up probably triggered the problem,
> but I'm now looking at a way to get the OSDs back up again.
>
> In the meantime I upgraded all the nodes to 0.61.4, but that didn't change
> anything.
>
> Any ideas on what this might be and how to resolve it?

At a guess, you can go in and grab the last good version of the OSD
Map and inject that back into the cluster, then restart the OSDs? If
that doesn't work then we'll need to figure out the right way to kick
them into being responsible for their stuff.
(First, make sure that when you turn them on they are actually
connecting to the monitors.)
-Greg
Software Engineer #42 @ http://inktank.com | http://ceph.com