[PATCH 05/26] loop: regularize upgrading the lock size for direct I/O

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



The LOOP_CONFIGURE path automatically upgrades the block size to that
of the underlying file for O_DIRECT file descriptors, but the
LOOP_SET_BLOCK_SIZE path does not.  Fix this by lifting the code to
pick the block size into common code.

Signed-off-by: Christoph Hellwig <hch@xxxxxx>
---
 drivers/block/loop.c | 25 +++++++++++++++----------
 1 file changed, 15 insertions(+), 10 deletions(-)

diff --git a/drivers/block/loop.c b/drivers/block/loop.c
index c658282454af1b..4f6d8514d19bd6 100644
--- a/drivers/block/loop.c
+++ b/drivers/block/loop.c
@@ -975,10 +975,24 @@ loop_set_status_from_info(struct loop_device *lo,
 	return 0;
 }
 
+static unsigned short loop_default_blocksize(struct loop_device *lo,
+		struct block_device *backing_bdev)
+{
+	/* In case of direct I/O, match underlying block size */
+	if ((lo->lo_backing_file->f_flags & O_DIRECT) && backing_bdev)
+		return bdev_logical_block_size(backing_bdev);
+	return 512;
+}
+
 static int loop_reconfigure_limits(struct loop_device *lo, unsigned short bsize)
 {
+	struct file *file = lo->lo_backing_file;
+	struct inode *inode = file->f_mapping->host;
 	struct queue_limits lim;
 
+	if (!bsize)
+		bsize = loop_default_blocksize(lo, inode->i_sb->s_bdev);
+
 	lim = queue_limits_start_update(lo->lo_queue);
 	lim.logical_block_size = bsize;
 	lim.physical_block_size = bsize;
@@ -997,7 +1011,6 @@ static int loop_configure(struct loop_device *lo, blk_mode_t mode,
 	int error;
 	loff_t size;
 	bool partscan;
-	unsigned short bsize;
 	bool is_loop;
 
 	if (!file)
@@ -1076,15 +1089,7 @@ static int loop_configure(struct loop_device *lo, blk_mode_t mode,
 	if (!(lo->lo_flags & LO_FLAGS_READ_ONLY) && file->f_op->fsync)
 		blk_queue_write_cache(lo->lo_queue, true, false);
 
-	if (config->block_size)
-		bsize = config->block_size;
-	else if ((lo->lo_backing_file->f_flags & O_DIRECT) && inode->i_sb->s_bdev)
-		/* In case of direct I/O, match underlying block size */
-		bsize = bdev_logical_block_size(inode->i_sb->s_bdev);
-	else
-		bsize = 512;
-
-	error = loop_reconfigure_limits(lo, bsize);
+	error = loop_reconfigure_limits(lo, config->block_size);
 	if (WARN_ON_ONCE(error))
 		goto out_unlock;
 
-- 
2.43.0





[Index of Archives]     [CEPH Users]     [Ceph Large]     [Ceph Dev]     [Information on CEPH]     [Linux BTRFS]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]

  Powered by Linux