On Mon, 2019-09-09 at 06:35 -0400, Jeff Layton wrote: > On Mon, 2019-09-09 at 11:28 +0100, Luis Henriques wrote: > > OSDs are able to perform object copies across different pools. Thus, > > there's no need to prevent copy_file_range from doing remote copies if the > > source and destination superblocks are different. Only return -EXDEV if > > they have different fsid (the cluster ID). > > > > Signed-off-by: Luis Henriques <lhenriques@xxxxxxxx> > > --- > > fs/ceph/file.c | 18 ++++++++++++++---- > > 1 file changed, 14 insertions(+), 4 deletions(-) > > > > Hi, > > > > Here's the patch changelog since initial submittion: > > > > - Dropped have_fsid checks on client structs > > - Use %pU to print the fsid instead of raw hex strings (%*ph) > > - Fixed 'To:' field in email so that this time the patch hits vger > > > > Cheers, > > -- > > Luis > > > > diff --git a/fs/ceph/file.c b/fs/ceph/file.c > > index 685a03cc4b77..4a624a1dd0bb 100644 > > --- a/fs/ceph/file.c > > +++ b/fs/ceph/file.c > > @@ -1904,6 +1904,7 @@ static ssize_t __ceph_copy_file_range(struct file *src_file, loff_t src_off, > > struct ceph_inode_info *src_ci = ceph_inode(src_inode); > > struct ceph_inode_info *dst_ci = ceph_inode(dst_inode); > > struct ceph_cap_flush *prealloc_cf; > > + struct ceph_fs_client *src_fsc = ceph_inode_to_client(src_inode); > > struct ceph_object_locator src_oloc, dst_oloc; > > struct ceph_object_id src_oid, dst_oid; > > loff_t endoff = 0, size; > > @@ -1915,8 +1916,17 @@ static ssize_t __ceph_copy_file_range(struct file *src_file, loff_t src_off, > > > > if (src_inode == dst_inode) > > return -EINVAL; > > - if (src_inode->i_sb != dst_inode->i_sb) > > - return -EXDEV; > > + if (src_inode->i_sb != dst_inode->i_sb) { > > + struct ceph_fs_client *dst_fsc = ceph_inode_to_client(dst_inode); > > + > > + if (ceph_fsid_compare(&src_fsc->client->fsid, > > + &dst_fsc->client->fsid)) { > > + dout("Copying object across different clusters:"); > > + dout(" src fsid: %pU dst fsid: %pU\n", > > + &src_fsc->client->fsid, &dst_fsc->client->fsid); > > + return -EXDEV; > > + } > > + } > > Just to be clear: what happens here if I mount two entirely separate > clusters, and their OSDs don't have any access to one another? Will this > fail at some later point with an error that we can catch so that we can > fall back? > Duh, sorry I asked before I had a cup of coffee this morning. The whole point is to skip that case. That said...I wonder if it's possible to have an fsid collision across two separate clusters and this fail to catch that case? Aren't these things just allocated via a simple counter increment? Probably not worth worrying about overmuch, but might be good to understand what would happen in that case if only to field mailing list reports. Other than that, this looks fine, modulo Ilya's comment about the two dout messages. > > > if (ceph_snap(dst_inode) != CEPH_NOSNAP) > > return -EROFS; > > > > @@ -1928,7 +1938,7 @@ static ssize_t __ceph_copy_file_range(struct file *src_file, loff_t src_off, > > * efficient). > > */ > > > > - if (ceph_test_mount_opt(ceph_inode_to_client(src_inode), NOCOPYFROM)) > > + if (ceph_test_mount_opt(src_fsc, NOCOPYFROM)) > > return -EOPNOTSUPP; > > > > if ((src_ci->i_layout.stripe_unit != dst_ci->i_layout.stripe_unit) || > > @@ -2044,7 +2054,7 @@ static ssize_t __ceph_copy_file_range(struct file *src_file, loff_t src_off, > > dst_ci->i_vino.ino, dst_objnum); > > /* Do an object remote copy */ > > err = ceph_osdc_copy_from( > > - &ceph_inode_to_client(src_inode)->client->osdc, > > + &src_fsc->client->osdc, > > src_ci->i_vino.snap, 0, > > &src_oid, &src_oloc, > > CEPH_OSD_OP_FLAG_FADVISE_SEQUENTIAL | -- Jeff Layton <jlayton@xxxxxxxxxx>