Hi,
I have 16 SAS disk on a LSI 9266-8i and 4 Intel 520 SSD on a HBA, the
node has dual 10G Ethernet. The clients are 4 nodes with dual 10GeB, as
test I use rados bench on each client. The aggregated write speed is
around 1,6GB/s with single replication.
In the first configuration, I had the SSDs on the raidcontroller as
well, but then I saturated the PCIe 2.0 x8 interface of the
raidcontroller, therefore I use a second controller for the SSDs.
-martin
Am 07.11.2012 17:41, schrieb Mark Nelson:
Well, local, but still over tcp. Right now I'm focusing on pushing the
osds/filestores as far as I can, and after that I'm going to setup a
bonded 10GbE network to see what kind of messenger bottlenecks I run
into. Sadly the testing is going slower than I would like.
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html