Re: global_init fails when only specifying monitor address

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Thursday, April 26, 2012 at 9:33 AM, Sage Weil wrote:
> On Thu, 26 Apr 2012, Wido den Hollander wrote:
> > Hi,
> > 
> > I tried to connect to a small Ceph setup on my desktop without cephx and that
> > failed:
> > 
> > root@stack01:~# ceph -m wido-desktop.widodh.nl:6789 (http://wido-desktop.widodh.nl:6789) -s
> > global_init: unable to open config file.
> > root@stack01:~#
> > 
> > I however worked with:
> > 
> > root@stack01:~# ceph -m wido-desktop.widodh.nl:6789 (http://wido-desktop.widodh.nl:6789) -c /dev/null -s
> > 2012-04-26 14:55:33.828524 pg v148: 594 pgs: 594 active+clean; 0 bytes
> > data, 7740 KB used, 70571 MB / 76800 MB avail
> > 2012-04-26 14:55:33.829622 mds e1: 0/0/1 up
> > 2012-04-26 14:55:33.836144 osd e14: 3 osds: 3 up, 3 in
> > 2012-04-26 14:55:33.886429 log 2012-04-26 14:52:50.674430 osd.1
> > [2a00:f10:11c:ab:52e5:49ff:fec2:c976]:6807/28366 12 : [INF] 1.2b scrub ok
> > 2012-04-26 14:55:33.892423 mon e1: 1 mons at
> > {desktop=[2a00:f10:11c:ab:52e5:49ff:fec2:c976]:6789/0}
> > root@stack01:~#
> > 
> > I quick look at global_init.cc (http://global_init.cc) showed me why this happened, it simply looks
> > for a configuration file to open and when it can't it fails.
> > 
> > But if a monitor address is set, a config file shouldn't be mandatory.
> > 
> > It could be accomplished rather simple by setting the flag
> > CINIT_FLAG_NO_DEFAULT_CONFIG_FILE if a mon_host has been set, but to do that
> > conf->parse_argv(args); should move a few lines up.
> > 
> > Comments? Thoughts?
> 
> I wonder if the simplest thing to do is:
> 
> - never error out on missing config in the default search path
> - always error out on missing config if it was explicitly specified via 
> -c foo or CEPH_CONF in environment.
> 
> ?
> 
> sage
I think this is probably right. I think that we may even error out correctly if we don't have values specified that we need, but we'll need to check that.
I'm working on similar stuff as I look at monitor cluster additions for Carl, so I'll look at this today.
-Greg 


--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html